Part No: RXSOL-40-4012-025
Organic Liquid corrosion inhibitor with low-toxic poerty provides long-life corrosion protection for closed cooling water systems . Rxsol Cool water Treat Corrosion Inhibitor will protect all commonly used materials in engine cooling water systems,
Cooling water Treatmanet Corrosion Inhibitor NCLT is specialized Cooling Water treatment chemicals for a closed re-circulating water system. Suitable for all types of engines where water circulation permitted. Major engine manufacturers such as MAN Diesel and Wartsila have a suggestion to use proper balance dose of Nitrite, Borate and organics based corrosion inhibitor in water circular line.
Liquid product, easy to use. Environmentally friendly, fully organic product, low toxicity. Effective against cavitation and erosion. Superior heat transfer properties. Compatible with hoses, gaskets and seals. Compatible with glycols for frost protection. Stable product - non-depleting. The product used for corrosion inhibition in many types of closed re-circulation system such as: - Diesel engine cooling water systems - Compressor cooling water systems - Centralised cooling systems - Hot water heating systems - Auxiliary machinery cooling systems.
Using Method : -
RXSOL Cool water Treat Corrosion Inhibitor is a highly effective corrosion inhibitor for all common metals in cooling water systems.Where most traditional inhibitors react with the metal surface and form oxides that prevent further corrosion, Cool water Treat Corrosion Inhibitor applies a thin and durable layer of protective molecules to the metal surfaces. This technology prevents the continuous build-up of insulating layers on heat transfer surfaces.
For new builds, RXSOL recommends cleaning of the water system before commercing service. The system will always contain small amounts of oil and iron oxides, and this can be easly removed in 1 time with Rxsol Commissioning Cleaner. If the system is corroded or is more heavily contaminated use Rxsol Degreaser HD. RXSOL Safe Acid for removal of metal oxides or scale is recommended.
For systems previously treated with other products, RXSOL Ships Service recommend to drain and flush the system before refilling with distilled water and Cool WATER treat . The system should be clean and free from scale and corrosion products when starting the treatment.
The use of antifreeze is sometimes required if the vessel is to be laid up in cold areas, Cool water Treat Corrosion Inhibitor can be used in conjunction with glycols for frost protection. If used in conjunction with glycols, It is recommended to increase the product concentration to 8%.
Dosing method
Cool water Treat Corrosion Inhibitor should be dosed to a suitable point in the system. If the expansion tank is used, adequate circulation must be assured.
Dosage and control
Cool water Treat Corrosion Inhibitor should always be present in a concentration of 5% or higher in the system. It is good practice to start with initial dose for an untreated system of 60 litres of Cool water Treat Corrosion Inhibitor /ton. 5% will provide sufficient protection of the system for a period of two to five years under normal conditions provided. To prevent residual falling below minimum level due to loss of cooling water, RXSOL Service recommend to maintain a level of 6% Cool water Treat Corrosion Inhibitor in the cooling system.
The engine manufacturer's recommendations for water quality should always be complied with. Cool water Treat Corrosion Inhibitor provides good protection even with contamination of the system by i.e. inorganc salts.Maintain Chloride levels and other contaminants at a minimum level. Most engine manufacturers recommend a maximum of 50 ppm Chlorides.
Physical Properties
Density 1.06
Packing, Type 25 Ltrs
Colour Colourless
Appearance Liquid
Cool water Treat Corrosion Inhibitor manufacturer and supplier in Mumbai, Gandhidham, Chennai Ennore, Visakhapatnam, Kolkata, Haldia, Hazira, Surat, Vizag, Fujairah, Sharjah, Ajman, Dubai, Muscat Canada, SUDAN, Yemen, Nairobi Kenya
RXSOL Cooling water Treatmanet Corrosion Inhibitor is an organic liquid corrosion inhibitor with low-toxic property provides long-life corrosion protection for closed cooling water systems RXSOL Cooling water Treatmanet Corrosion Inhibitor will protect all commonly used materials in engine cooling water systems, including aluminium. Cooling water Treatmanet Corrosion Inhibitor does not contain components subject to rapid depletion. Cool WATER treat is stable and biodegradable
"Product Code" - Chemical Description SPECIFICATION .
| Sl. No. | Product Code | Chemical Description | Specification / Performance Requirement |
|---|---|---|---|
| 1 | RXSOL-44-6119-025 | Oxygen Scavenger – Sodium Bisulphite (For Water Injection) | To maintain DO below 20 ppb. Minimum strength 40%. Compatibility report with the membrane to be provided. |
| 2 | RXSOL-81-8171-025 | Injection Water Corrosion Inhibitor | Residual CI > 20% of dosing ppm. Fe in Injection Water < 0.05 ppm. |
| 3 | RXSOL-43-4098-025 | Biocide Disperser | SRB population < 100 cfu/mL. Minimum active ingredient concentration 50%. |
| 4 | RXSOL-42-1308-030 | Sodium Hydroxide (NaOH), 48 wt% Concentration | To maintain pH 10–11 during CEB and CIP and remove membrane fouling. Minimum concentration 48%. |
| 5 | RXSOL-43-8936-025 | Membrane Biocide for SRU & Wash Water Membranes | Polyglycol and DBNPA based. Must have compatibility certificate for DOW SRU membranes. Minimum active compound 20%. |
| 6 | RXSOL-25-3025-026 | Sodium Hypochlorite (NaOCl), 12.5 wt% Concentration | Maintain SRB population < 100 cfu/mL. Minimum concentration 12.5%. |
| 7 | RXSOL-19-1101-025 | Hydrochloric Acid (HCl), 25 wt% Concentration | To maintain pH 2–3 during CEB and CIP and remove membrane fouling. Minimum concentration 25%. |
| 8 | RXSOL-33-3302-025 | Scale Inhibitor / Antiscalant for SRU & Wash Water | Prevent scale formation in membranes. Maximum dosage rate 4 ppm. Must have compatibility certificate for DOW SRU membranes. |
| 9 | RXSOL-40-5024-025 | pH Controller | To maintain TEG pH > 7. Estimated quantity as per operational requirements. |
| 10 | RXSOL-33-3302-250 | Topside Scale Inhibitor | Residual SI > 20% of dosing ppm. Scaling Tendency Efficiency by Titration > 80%. |
| 11 | RXSOL-40-4029-030 | Topside Corrosion Inhibitor (Liquid) | Residual CI > 20%. ΔFe < 2 ppm. Corrosion Rate < 4 MPY. |
| 12 | RXSOL-40-4012-025 | Corrosion Inhibitor for Cooling Water | Residual CI > 20% of dosing ppm. Additional Monitoring Parameter: Corrosion Rate < 3 MPY. |
WHERE USED:
- RR WEST UNITS
- CBDC UNIT U-2026: USED IN FRESH COOLING WATER SYSTEM (U-2026) OF CBDC TO PROTECT CARBON STEEL AS WELL AS YELLOW METALLURGY OF FCW COOLERS. FROM CORROSION AND CONTAINS PH BUFFERS TO DEFEND THE SYSTEM AGAINST PH CHANGES.
NOTE :
- SHELF LIFE REQUIRED IS 2 YEARS (MINIMUM) FROM DATE OF PRODUCTION
Item Specs:
GENERIC TYPE: CORROSION INHIBITOR
FORM: LIQUID
SERVICE: WATER TREATMENT
CHEMICAL,PROCESS, CORROSION INHIBITOR, LIQUID KG
COMPOSITION / INFORMATION ON INGREDIENTS:
- AN AQUEOUS SOLUTION OF SODIUM NITRITE
- Content : SODIUM NITRITE
- CAS # 7632-00-0
PHYSICAL AND CHEMICAL PROPERTIES
=================================
- PHYSICAL STATE : LIQUID
- ODOUR : MILD
- PH : 12.5 13.5
- FREEZING POINT : < - 10 °C
- INITIAL BOILING POINT : > 100 °C
- SOLUBILITY IN WATER : COMPLETE
- COLOR : PINK
Safety Data (MSDS)

| Product Name | RXSOL-40-4012-025 |
| Product Type | Cool water Treat Corrosion Inhibitor |
Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
Stock Point : Mumbai, Kandla, Kolkata, Chennai, Visakhapatnam, Fujairah, Muscat, Canada
| Phone | +91 22 65113333 / 5555 / 9999 / 27611360 |
| Fax | +91 22 2781 1318 :::AOH :0091 9821214367 |
| mail@rxmarine.com |

|
Chemical Name |
Concentration |
CAS Number |
EC Number |
R Phrases* |
Symbols Disodium |
| Proprietory percentage composition of nitrite, borate and organics based corrosion inhibitor | 20 - 30 | ---Blend | ---Blending Mixture | --- | --- |
|
Ethylhexanoic compound, |
10-15 |
N/A |
205-743-6 |
63 |
Xn |
|
2-sodium salt Tolyltriazole |
1-3 |
29385-43-1 |
29385-43-1 |
22 |
Xn |
|
Non classified ingredients |
60-100 |
|
|
|
*See Section 16

|
Odour |
odourless |
|
Appearance |
Liquid, colourless, soluble in water |
|
Contact with eyes |
Causes redness and irritation |
|
Contact with skin |
In cases of severe exposure, severe irritation may develop |
|
Inhalation |
Vapours or aerosols may cause irritation of eyes, nose and respiratory tract |
|
Ingestion |
The ingestion of significant quantities may cause gastro-intestinal disturbances |

|
Contact with skin |
Wash affected area with plenty of soap and water |
|
Contact with eyes |
If substance has got into eyes, immediately wash out with plenty of water for at least 15 minutes |
|
Ingestion |
|
|
Inhalation |
|
|
General |
In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible) (S45) |

|
Fire-fighting measures |
|

|
Personal Precautions |
Wear protective clothing as per section 8 |
|
Environmental Precautions |
Do not allow to enter public sewers and watercourses |
|
Clean Up Actions |
|

|
Handling |
- Wear protective clothing as per section 8 - Avoid contact with skin and eyes (S24/25) - Eyewash bottles should be available |
|
Storage |
- Keep in a cool, dry, well ventilated place - Protect from frost - Protect from heat |

|
Exposure Limits |
There are no recommended or established controls for this product |
|
Exposure controls |
The undiluted product must not be used in a confined space without good ventilation |
|
Occupational exposure controls |
- No respiratory protection is required unless subject to contact with substance mist - Wear suitable protective clothing, including eye/face protection and gloves (plastic or rubber are recommended)
|
Gloves Goggles Suit No_Smoking

|
Odour |
Odourless |
|
Appearance |
Liquid, colourless, soluble in water |
|
pH |
8.2 at 5 % concentration, pH ~ 9.5 at 100 % concentration |
|
Vapour pressure |
not known |
|
Freezing point |
0 °C to 760 °C |

- This article is considered stable under normal conditions
- Avoid overheating, Keep away from frost
- Incompatible with strong oxidizing substances, Contact with acids liberates toxic gas (R31)
- See Section 5

|
Toxicological information |
- Possible risk of harm to the unborn child (R63) - In cases of severe exposure, redness and irritation may develop - The ingestion of significant quantities may cause nausea/vomiting |
|
Contact with skin |
In cases of severe exposure, severe irritation may develop |
|
Contact with eyes |
Causes redness and irritation |
|
Ingestion |
- The ingestion of significant quantities may cause gastro-intestinal disturbances - May cause nausea/vomiting |
|
Carcinogenicity |
No evidence of carcinogenic effects |

|
|

- Do not discharge into drains or the environment, dispose to an authorised waste collection point
- Disposal should be in accordance with local, state or national legislation

- Not classified as hazardous for transport

|
Risk Phrases |
Possible risk of harm to the unborn child (R63) |
|
Safety Phrases Irritant |
- Wear suitable gloves and eye/face protection (S37/39) - If swallowed seek medical advice immediately and show this container or label (S46) |

Text of R and S phrase codes used in this safety data sheet:- R34: Causes burns; R36: Irritating to eyes; R37: Irritating to respiratory system; R41: Risk of serious damage to eyes. The information provided about the product on this Safety Data Sheet has been compiled from knowledge of the individual constituents The data given here is based on current knowledge and experience. This Safety Data Sheet describes the product in terms of safety requirements and does not signify any warranty with regard to the product's properties The data given here only applies when product used for proper application(s). The product is not sold as suitable for other applications - usage in such may cause risks not mentioned in this sheet. Do not use for other application(s) without seeking advice from manufacturer
DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable..