Part No: RXSOL-19-1016-025
It controls foaming in sewage and waste water systems and collecting tanks in vaccum toilet systems.
Sewage Defoamer – High-Performance Foam Control Solution for Sewage Treatment Plants
Foam formation is a common challenge in sewage treatment plants (STPs), wastewater treatment plants (WWTPs), industrial effluent treatment plants (ETPs), and marine sewage systems. Excessive foam can reduce treatment efficiency, interfere with aeration, cause overflow, and increase maintenance costs. Sewage Defoamer is a specially formulated antifoaming agent designed to provide rapid and long-lasting foam control in sewage and wastewater treatment applications.
This is a non- silicone based water dispersible, liquid emulson. It controls foaming in sewage and waste water systems and collecting tanks in vaccum toilet systems.
RXSOL-16-2066-210 is antifoam emulsion and its more concentrated antifoam emulsion. It has excellent candidates for controlling foam in amine and glycol dehydration units. This is suitable products for gas plants and have excellent stability in the presence of salts, resulting in reduced deposits on the plant’s equipment. RXSOL-16-2066-210 help preserves foam control under the severe conditions of a dehydrating unit. These conditions can remove water from other antifoam emulsions, rendering them immediately inactive.
Antifoam Defoamer is a very efficient and stable emulsion designed for a variety of aqueous systems. It may be used as received or dilute for specific applications.
Typical dosage is 10 to 30 ml / ton, but proper dosage rate to be found out on site testing. The recommended dosing method for sewage system is to premix 1 part of RXSOL-19-1016 with 5 parts of fresh water and pump this into the EVAC ejector tank . The dosing is done about 1/2 hour before top load.
Sewage Defoamer manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of Sewage Defoamer at a competitive price from us. We have ready stock of Sewage Defoamer in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.
Sewage Defoamer – High-Performance Foam Control Solution for Sewage Treatment Plants
Foam formation is a common challenge in sewage treatment plants (STPs), wastewater treatment plants (WWTPs), industrial effluent treatment plants (ETPs), and marine sewage systems. Excessive foam can reduce treatment efficiency, interfere with aeration, cause overflow, and increase maintenance costs. Sewage Defoamer is a specially formulated antifoaming agent designed to provide rapid and long-lasting foam control in sewage and wastewater treatment applications.
What is Sewage Defoamer?
Sewage Defoamer is a high-performance liquid antifoam formulated to eliminate and prevent foam formation in biological and industrial wastewater treatment systems. It quickly penetrates foam bubbles, causing them to collapse while preventing new foam from forming.
Suitable for both continuous dosing and shock treatment, it ensures smooth plant operation without affecting the biological treatment process when used as recommended.
Key Features
-
Rapid foam knockdown action
-
Long-lasting foam suppression
-
Effective in biological and industrial wastewater
-
Suitable for aerobic and anaerobic treatment systems
-
Easy to dose and disperse
-
Compatible with automatic dosing systems
-
Helps improve operational efficiency
-
Reduces maintenance and cleaning requirements
Applications
-
Sewage Treatment Plants (STPs)
-
Wastewater Treatment Plants (WWTPs)
-
Effluent Treatment Plants (ETPs)
-
Marine sewage treatment systems
-
Industrial wastewater treatment
-
Equalization tanks
-
Aeration tanks
-
Clarifiers
-
Sludge processing units
-
Biogas and anaerobic digesters
Benefits
Fast Foam Elimination
Instantly breaks down excessive foam and prevents overflow.
Improves Treatment Efficiency
Maintains proper aeration and enhances biological treatment performance.
Reduces Maintenance
Prevents foam-related operational problems and minimizes downtime.
Cost-Effective
Low dosage requirements provide economical and reliable foam control.
Easy to Use
Can be added manually or through automated dosing systems.
Typical Dosage
The recommended dosage depends on foam intensity and wastewater characteristics:
-
Initial dosage: 10–100 ppm
-
Maintenance dosage: Adjust according to system requirements
For optimum performance, conduct a small-scale trial before full-scale application.
Typical Properties
| Property | Typical Value |
|---|---|
| Appearance | White to off-white liquid |
| Type | Silicone-based or Non-silicone (available as required) |
| Solubility | Easily dispersible in water |
| pH | Neutral |
| Application | Foam control in wastewater treatment |
Industries Served
-
Municipal sewage treatment plants
-
Marine and shipping
-
Food processing industries
-
Chemical manufacturing
-
Textile processing
-
Paper and pulp mills
-
Pharmaceutical plants
-
Petrochemical industries
-
Dairy and beverage processing
Why Choose Our Sewage Defoamer?
Our Sewage Defoamer is engineered to deliver fast, efficient, and long-lasting foam control in demanding wastewater treatment environments. It helps maintain stable plant operation, improves treatment efficiency, and reduces operating costs, making it the ideal solution for municipal, marine, and industrial wastewater systems.
Sewage Defoamer, Wastewater Defoamer, STP Defoamer, ETP Antifoam, Wastewater Antifoam Chemical, Sewage Treatment Foam Control, Silicone Defoamer for Sewage, Marine Sewage Defoamer, Foam Control Chemical, Industrial Wastewater Defoamer, Biological Treatment Defoamer, Wastewater Treatment Chemicals.
38249090
ACGIH is the American Conference of Governmental Industrial Hygienists. It recommends upper limits (called TLVs) for exposure to workplace chemicals.
General-purpose antifoams have a wide range of applicability, but not all of them are suitable for use in the treatment of gas. Some foam control agents can aggravate the problem. Foam control in gas scrubbers is only one of the process parameters to be monitored. It is equally important to prevent or slow the fouling of the unit, because dismantling of the gas-scrubbing units is manually intensive. Incorrectly specified antifoams can easily lead to increased fouling and clogging, particularly in the heat exchangers. Momentive Performance Materials RXSOL antifoams are designed to provide foam control with a minimum of such problems.
Antifoam Defoamer is a cost-effective and economical defoamer designed for a wide range of food-grade and food processing applications as well as general industrial applications in paper making, textiles, paints and coatings, and
This antifoam compound are targeted for gas recovery plants, where natural gas must be washed, or scrubbed, before distribution, and for liquefied natural gas (LNG) plants that must achieve high gas purity before liquefaction.
In many amine units, foam can be problematic. Proper line control without antifoam is, generally, extremely difficult.
Food Processing & Agribusiness
Water Treatment
Paint Inks and Coatings, & Adhesives (PICA)
Chemical Manufacturing
Cleaning Compounds
Processes Pulp Paper
Oil and gas
Mining
Recycle mills, sulfite mills, and kraft mills all rely on antifoams and defoamers. Foam buildup can lead to slower production rates, low-quality output, increased use of bleaching, inefficient washing, and maintenance problems.
Safety Data (MSDS)

| Product Name | RXSOL-19-1016-025 |
| Product Type | Defoamer |
Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
| Phone | +91 22 65113333 / 5555 / 9999 / 27611360 |
| Fax | +91 22 2781 1318 :::AOH :0091 9821214367 |
| 123@rxmarine.com |

|
Chemical Name |
Concentration |
CAS Number |
EC Number |
R Phrases* |
Symbols |
| Polymer Formulated | 30 - 35 | Proprietory | --- | --- | --- |
|
Etheralcohol |
25 |
98072-31-2 |
308-482-7 |
53 |
- |
*See Section 16

|
Odour |
Characteristic odour. |
|
Appearance |
Liquid, colourless to yellow, dispersible in water. |
|
Contact with eyes |
Mildly irritating to eyes. |
|
Contact with skin |
Incases of severe exposure, irritation may develop. |
|
Inhalation |
Vapours or aerosols may cause irritation of eyes, nose and respiratory tract. |
|
Ingestion |
May cause gastro-intestinal disturbances. |

|
Contact with skin |
Remove contaminated clothing immediately and drench affected skin with plenty of water. Then wash with soap and water. Seek medical attention if irritation persists |
|
Contact with eyes |
If sub stance has got into eyes, immediately wash out with plenty of water for at least 15minutes. Seek medical advice |
|
Ingestion |
Never make an unconscious person vomit or drink fluids.Do not induce vomiting.Give water or milk to drink. Seek medical advice |
|
Inhalation |
In halation is unlikely to occur.Remove patient to fresh air |
|
General |
In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible) ( S45 ) |

- Decomposition productsmay include carbondi oxide
- In case of fire use water spray or fog, alcohol resistant foam, dry chemical or carbon dioxide ( S43 )
- Wear Breathing Apparatus

|
Personal Precautions |
Wear protective clothing as per section 8.Spillage causes slippery surface. |
|
Environmental Precautions |
Use appropriate containment to avoid environmental contamination ( S57 ). |
|
Immediate Actions |
Shut off source of leak if safe to do so |
|
Clean Up Actions |
Absorb spillage in inert material and shovel up.Ventilate the are a and wash spill site after material pick- up is complete. |
|
Special Precautions |
Wear protective clothing as per section 8. |

|
Handling |
The usual precautions for handling chemicals should be observed |
|
Storage |
Keep only in the original container in a cool, well ventilated place ( S3/9/49.Protect from frost |

|
Exposure Limits |
There are no recommended or established controls for this product |
|
Exposure controls |
No special |
|
|
precautions are required for this productOccupational exposure controls.Wear suitable protective clothing, including eye /face protection and gloves ( plastic or rubber are recommended ).No respiratory protection is required unless subject to contact with substance mis t.Respiratory protection may be required under exceptional circumstances when excessive air.contamination exists.....Suit |
![]()
Gloves Suit Goggles

|
Appearance |
Liquid, colour less to yellow, dispersible in water |
|
Boiling point & gt; |
100°C at 760m m /Hg |
|
Vapour pressure |
not known |
|
Emulsifies in water |
|
|
Specific gravity ( water=1 ) |
0.85 |
|
Viscosity |
500-1500mPa .sat 20 deg C |

No hazardous decomposition products known
Avoid overheating, Keep away from frost, Keep away from strong oxidizing substances (S14)

|
Toxicological information |
LD50 (oral,rat) >2000 mg/kg |
|
Inhalation |
May cause irritation |
|
Contact with skin |
In cases of severe exposure, redness and irritation may develop |
|
Contact with eyes |
May cause redness and irritation |
|
Ingestion |
The ingestion of significant quantities may cause gastro-intestinal disturbances Aspiration hazard |

|
Ecotoxicity |
This product contains components which are classified in the EU as dangerous for the environment.On available data, substance is not harmful to aquatic life.LC50 (fish) >100 mg/l (96 hr) |
|
Mobility |
Emulsifies in water |
|
Persistence and Biodegradability |
Not readily biodegradable BOD28/COD 60% |
|
Bioaccumulation Potential |
No information available |
|
Other Adverse Effects |
No environmental problems are expected when the product is used / handled correctly. |

Disposal considerations: Do not discharge into drains or the environment, dispose to an authorised waste collection point. Disposal should be in accordance with local, state or national legislation

Not classified as hazardous for transport

|
Classification and labelling |
Not classified as hazardous for users |
|
Risk Phrases |
Not applicable |
|
Safety Phrases |
Not applicable |

Text of R and S phrase codes used in this safety data sheet:- R53: May cause long term adverse effects in the aquatic environment. The information provided about the product on this Safety Data Sheet has been compiled from knowledge of the individual constituents .The data given here is based on current knowledge and experience. This Safety Data Sheet describes the product in terms of safety requirements and does not signify any warranty with regard to the product's properties The data given here only applies when product used for proper application(s). The product is not sold as suitable for other applications - usage in such may cause risks not mentioned in this sheet. Do not use for other application(s) without seeking advice from manufacturer
DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.