Part No: RXSOL-60-6001-210
Boiler water treatment product, formulated with polymer scale inhibitors, alkaline compounds, phosphates and condensate protecting amines.
VapourTreatment For controlling of Scale & Foam ::: Neutral Liquid for prevention of scale in seawater Evaporators
This is a highly Active Antifoulant, Water Scale Inhibitor, Dispersant and Anti-precipitant compound for use in industrial and Marine Water systems, such as cooking systems, Heat Exchangers, air conditioning equipment, etc.
Procedure Of Use and Dose Rates: POLYELECTROLYTE polymer of RXSOL-51-6001-025 reacts with the potential scale forming salts in the water to prevent them from adhering to heat transfer surfaces. These solids are held in suspension and easily removed from the evaporator line. Finally RXSOL-51-6001-025 also have defoaming properties by which will stop foaming in EVAPORATOR. And by that way Distilled water quality is maintained in side the EVAPORATOR.
Used in both high and low pressure evaporators.
Dosage :
| Daily Out Put Evaporator | Daily RXSOL VT 6001 Requirement |
| 10 -20 MT | 100-200 ML |
| 30-40 MT | 300-400 ML |
| 50-60 MT | 500-600 |
Setting the Flow Rate: The treatment is added to the dosage tank and mixed with water. Example: With the 0.5 litres of Vaptreat add sufficient water to make up 50 litres of liquid.The standard flow meter is Adjustable-Rate=0-l00ml/minute.Flow rate calculation: Flowrate = 50 Litres/24 x 60= 35 ml/min setting i.eThis will last 24 hours.
Note: We can remove existing mineral scale deposits by using A 5-10% solution of RXSOL-51-6001-025 Otherwise to save money and cleaning of HARD DEPOSITS which is formed due to not proper treratment of Evaporator, we have specialized Safe Scale Remover with Indicator ( Product code is RXSOL-22-2210-200 ).
| CharactersItics | Properties | |
| Appearance Thermal Firmness | Clear yellow liquid 250° C | By keeping heat transfer surfaces free of scale, Ensures that the evaporator works at maximum efficiency. |
| Density | In g/cm3 at 15°C: 1.1 |
Permits more efficient evaporation. |
| pH (1 Vol%) | 9 |
Reduces downtime and maintenance costs. |
| Compatibility | Concentrated, safe liquid, easy and economical dosing. | |
| Metal | No known effect |
For use in both high pressure and vacuum evaporators |
| Rubber | No known effect | The antifoaming properties ensure that distillate quality is high |
| Packaging |
20 / 25 ltr |
Improves the quality of distilled water |
Frequently Asked Questions (FAQs) – Industrial Water Treatment & Cleaning Chemicals
Q1. Why are Cooling Tower Treatment Chemicals required?
Ans. Cooling tower chemicals help maintain water quality by controlling scale formation, corrosion, microbial growth and fouling. They improve heat-transfer efficiency, protect equipment and support reliable cooling system performance.
Q2. Why are Boiler Water Treatment Chemicals required?
Ans. Boiler water treatment chemicals maintain the required water quality for efficient steam generation. They help prevent scale deposits, corrosion, oxygen-related damage and sludge accumulation, improving boiler efficiency and operational reliability.
Q3. Why are Tank Cleaning Chemicals required?
Ans. Tank cleaners are used to remove oil, grease, sludge, rust, chemical residues and other contaminants from Mild Steel (MS) and Stainless Steel (SS) tanks. Proper cleaning supports safe tank maintenance, product purity and preparation for subsequent use.
Q4. Why are Evaporator Treatment Chemicals required?
Ans. Evaporator treatment chemicals are used to remove scale, mineral deposits, sludge and fouling from Effluent Treatment Plant (ETP) evaporators. They help restore heat-transfer efficiency, maintain evaporation performance and reduce operational problems caused by deposits.
Why Evaporator Treatment Chemicals must use?
PREVENTION OF SCALING IN SEA WATER EVAPORATORS.
RXSOL Vapor Treatment Prevents scale formation at temperatures up to 160°C Also Reduces foaming and maintains optimum plant performance.
Dilute the RXSOL VAPOR TREATMENT chemicals with water and continuously inject via evaporator inlet or the salt water supply lineand dose into the evaporator system. 30 ml Dose per ton of Seawater is recommended for the prevention of scaling in seawater evaporators. Dose can vary depends on the capacity and the operating conditions of the evaporator.
OTHER VALUABLE MARINE CHEMICALS available in UAE INDIA OMAN:::
RXSOL-51-6001-025 is a concentrated solution of a POLYELECTROLYTE polymer and Antifoaming Agents for use in SEA WATER evaporator as a controller of scale and foam in side the evaporators. It can be used as a scale inhibitor in the feed water to EVAPORATORS producing fresh water .
A liquid polymer-based evaporator treatment specially designed to control and prevent scale formation in evaporators
LIQUIVAP TREAT used in Sea Water Distillation Plant to control Alkaline SCALE due to presence of Alkaline Materials like calcium carbonate and magnesium hydroxide.
Water blend of Polymaleic acid. LIQUIVAP TREAT is a highly concentrate liquid product to prevent scaling in all types of seawater distillation plant. LIQUIVAP TREAT is a concentrated formula polymeric scale inhibitor of low molecular weight for the prevention of scale in salt or fresh water, flash
Where LIQUIVAP TREAT can be used ?
What is LIQUIVAP TREAT?
LIQUIVAP TREAT is a high-performance, polymer-based scale inhibitor specifically designed for seawater distillation plants, including multi-stage flash (MSF) and multi-effect distillation (MED) systems. It is a concentrated liquid formulation based on polymaleic acid, engineered to control alkaline scale deposits such as calcium carbonate (CaCO₃) and magnesium hydroxide (Mg(OH)₂).
Why Is LIQUIVAP TREAT Important?
In seawater distillation, scale formation on heat transfer surfaces severely affects:
-
Thermal efficiency
-
Production output
-
Operating costs
-
Equipment longevity
LIQUIVAP TREAT is vital because it:
-
Prevents scale formation by dispersing and sequestering alkaline materials before they crystallize
-
Enhances heat exchange efficiency
-
Reduces energy consumption and downtime
-
Prolongs plant equipment lifespan
Role of LIQUIVAP TREAT in Seawater Distillation Plants
Core Functions:
-
Scale Control: Inhibits formation of hard scales like calcium carbonate and magnesium hydroxide.
-
Polymeric Action: The polymaleic acid blend interferes with crystal growth and keeps potential scale-forming compounds in suspension.
-
Surface Protection: Reduces deposition on evaporator tubes and heat transfer surfaces.
-
Anti-Foaming Support: Helps prevent foaming when used in synergy with anti-foam agents, ensuring smoother operation.
Effective For:
-
Multi-stage flash distillation (MSF)
-
Multi-effect distillation (MED)
-
High and low-pressure evaporators
-
Saltwater and brackish water systems
Where Can LIQUIVAP TREAT Be Used?
LIQUIVAP TREAT is ideal for:
-
Power & desalination plants
-
Marine distillation units (ships, rigs)
-
Industrial water recovery systems
-
Municipal seawater desalination projects
It is suitable for use in:
-
High-pressure evaporators
-
Low-pressure evaporators
-
Systems requiring continuous anti-scaling treatment
Summary of Benefits
| Feature | Benefit |
|---|---|
| Polymaleic acid base | Strong inhibition of CaCO₃ & Mg(OH)₂ |
| Liquid concentrate format | Easy dosing and mixing |
| Thermal stability | Effective across wide temperature range |
| Low molecular weight | Ideal for fast-acting dispersion |
| Wide applicability | Compatible with all major plant types |
LIQUIVAP TREAT is more than just a scale inhibitor — it’s an essential component in protecting your distillation investment. Regular use ensures:
-
Stable plant output
-
Reduced maintenance
-
Improved water quality
-
Lowered operational costs
By controlling alkaline scale before it forms, LIQUIVAP TREAT plays a critical role in maximizing efficiency and uptime in any seawater distillation operation.
Safety Data (MSDS)
![]()
| Product Name | RXSOL-60-6001-210 |
| Product Type | LIQUIVAP TREAT |
Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
Stock Point : Mumbai, Kandla, Chennai, Kolkata, Visakhapatnam, Fujairah, Muscat
| Phone | +91 22 27815540 / 41 / 42 |
| Fax | +91 22 2781 1318 :::AOH :0091 9821214367 |
| mail@rxmarine.com |

|
Chemical Name |
Concentration |
CAS Number |
EC Number |
R Phrases* |
Symbols |
|
Sodium Acrylate |
10-30 |
25085-02-3 |
N/A |
- |
- |
|
Sodium Gluconate Mixture |
10-20 |
|
|
|
|
| EDTA Blend | 5-10 | ||||
| Proprietary Blend of various Phosphonate | 20-25 |
*See Section 16

|
Odour |
Odourless |
|
Appearance |
Liquid, pale yellow, soluble in water |
|
Contact with eyes |
Mildly irritating to eyes |
|
Contact with skin |
In cases of severe exposure, irritation may develop |
|
Inhalation |
Vapours or aerosols may cause irritation of eyes, nose and respiratory tract |
|
Ingestion |
May cause gastrointestinal disturbances |

|
Contact with skin |
Remove contaminated clothing immediately and drench affected skin with plenty of water. Then wash with soap and water Seek medical attention if irritation persists |
|
Contact with eyes |
If the substance has got into eyes, immediately wash out with plenty of water for at least 15 minutes Seek medical advice |
|
Ingestion |
Never make an unconscious person vomit or drink fluids Give water or milk to drink When in doubt or symptoms persist, seek medical attention |
|
Inhalation |
is unlikely to occur Remove patient to fresh air |
|
General |
In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible) |

- Non combustible
- Smoke from fires is irritating
- Not flammable. In case of fire use extinguishing media appropriate to surrounding condition

|
Personal Precautions |
Wear protective clothing as per section 8. |
|
Environmental Precautions |
No special precautions are required for this product. |
|
Immediate Actions |
Shut off the source of leak if safe to do so. |
|
Clean Up Actions |
Flush spill area with copious amounts of water. |
|
See SeSpecial Precautions |
Wear protective clothing as per section 8 No special precautions are required for this product. |

|
Handling |
The usual precautions for handling chemicals should be observed |
|
Storage |
Keep only in the original container in a cool, well ventilated place (S3/9/49 |

|
Exposure Limits |
There are no recommended or established controls for this product. |
|
Exposure controls |
No special precautions are required for this product. |
|
Occupational exposure controls |
Wear suitable protective clothing, including eye/face protection and gloves (plastic or rubber are recommended). |
![]()
Gloves Suit Goggles

|
Odour |
Odourless |
|
Appearance |
Liquid, colouless or pale yellow, soluble in water |
|
pH |
8.5 - 10 at 100 % concentration |
|
Boiling point |
>100 °C at 760 mm /Hg |
|
Vapour pressure |
not known |
|
Freezing point |
0 °C at 760 mm/Hg |
|
Completely soluble in water |
|
|
Specific gravity (water=1) |
1.08 |
|
Non |
combustible |

- No hazardous decomposition products known
- Avoid overheating, Keep away from frost

|
Toxicological information |
LD50 (dermal) : > 10000 mg/kg No effects in humans. |
|
Inhalation |
Vapours or aerosols may cause irritation of eyes, nose and respiratory tract. |
|
Contact with skin |
In cases of severe exposure, redness and irritation may develop. |
|
Contact with eyes |
In cases of severe exposure, redness may develop. |
|
Ingestion |
In cases of severe exposure, gastro-intestinal disturbances may develop. |
|
Carcinogenicity |
No evidence of carcinogenic effects. |

|
Ecotoxicity |
On available data, the substance is not harmful to aquatic life LC50 (bluegill sunfish) 4750 mg/l (96 hr) (Sodium acrylate). |
|
Mobility |
Completely soluble in water. |
|
Persistence and Biodegradability |
Most components in this product are not readily biodegradable. Sodium polyacrylate: Chemical oxygen demand (COD) 0.4 g/g Biological oxygen demand (BOD) 0.009 g/g. |
|
Bioaccumulation Potential |
Bioaccumulation is insignificant. |
|
Other Adverse Effects |
Presents little or no hazard to the aquatic environment. |

|
Classification |
EU Waste class. |
|
Disposal considerations |
Do not discharge into drains or the environment, dispose to an authorised waste collection point Disposal should be in accordance with local, state or national legislation. |

- Not classified as hazardous for transport

|
Classification and labelling |
Not classified as hazardous for users |
|
Risk Phrases |
Not applicable |
|
Safety Phrases |
Not applicable |

The information provided about the product on this Safety Data Sheet has been compiled from knowledge of the individual constituentsThe data given here is based on current knowledge and experience. This Safety Data Sheet describes the product in terms of safety requirements and does not signify any warranty with regard to the product's properties The data given here only applies when product used for proper application(s). The product is not sold as suitable for other applications usage in such may cause risks not mentioned in this sheet. Do not use for other application(s) without seeking advice from manufacturer .