Part No: RXSOL-60-6605-537
Sodium Molybdate main uses in catalyst, Poultry Feed, Cattle Feed, Fertilizer and Pigment.
Sodium molybdate supplier in small and large packing. Sodium Molybdate main uses in catalyst, Poultry Feed, Cattle Feed, Fertilizer and Pigment. We are major EXPORTER of Sodium Molybdate for various industries.
Manufacturers of Molybdenum Compounds in India.We are specialized in producing Ammonium Molybdate, Sodium Molybdate, Molybdic acid, Molybdenum Trioxide, Molybdenum Sulphide, Potassium Molybdate and Lithium Molybdate.
Sodium molybdate has the advantage in that the dosing of lower ppm's of molybdate allow for lower conductivity of the circulating water. Sodium molybdate at levels of 50-100 ppm offer the same levels of corrosion inhibition that sodium nitrite at levels of 800+ ppm. By utilizing lower concentrations of sodium molybdate, conductivity is kept at a minimum and thus galvanic corrosion potentials are decreased.
Na2MoO4.2H2O - Useful corrosion inhibitior for cooling tower system, Lower concentrations of sodium molybdate can decreased the corrosion while sodium nitrite levels 800+ ppm required to stop corrosion.
RXSOL CHEMO PHARMA INTERNATIONAL
SODIUM MOLYBDATE DIHYDRATE - TECHNICAL DATA SHEET
|
Appearance |
White crystalline powder |
|
Packing |
25 KG BAG Net weight |
|
Characteristic |
Min. value |
Max value |
|
Na2MoO4.2H2O purity |
99.5% |
101% |
|
Moisture at 105 degrees C |
14% |
14.90% |
|
Mo |
39% |
40% |
|
Insoluble in water |
|
0.05% |
|
pH 5% solution |
7 |
10 |
Note: Values above are reproduced from the supplied technical data and are fully editable in this document.
SODIUM MOLYBDATE AR DIHYDRATE manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai, Sharjah, UAE, Gulf, Middle East, Muscat Oman, Kenya Africa. Get the best quality of SODIUM MOLYBDATE AR DIHYDRATE at a competitive price from us. We have ready stock of SODIUM MOLYBDATE AR DIHYDRATE in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.
RXSOL Brand is popular as a water treatment chemicals Company in India, UAE, Oman, Nairobi, and Sudan. Some of our water treatment chemicals RAW MATERIALS product list.
| 1 | Cyclohexylamine | CHA | 108-91-8 |
| 2 | Morpholine | MORPH | 110-91-8 |
| 3 | 3-Methoxypropylamine | MOPA | 5332-73-0 |
| 4 | N,N-Diethylhydroxylamine | DEHA | 3710-84-7 |
| 5 | Hydrazine Hydrate | HH | 10217-52-4 |
| 6 | Carbonyl Dihydrazine | CBDH | 497-18-7 |
| 7 | Acetone Oxime | DMKO | 127-06-0 |
| 8 | EDTA-2Na | EDTA-2Na | 6381-92-6 |
| 9 | EDTA-4Na | EDTA-4Na | 10378-23-1 |
| 10 | 2,2-Dibromo-2-Cyanoacetamide | DBNPA | 10222-01-2 |
| 11 | Benzalkonium Chloride | BAC | 63449-41-2 |
| 12 | Polyhexamethylene Guanidine | PHMG | 57028-96-3 |
| 13 | Sodium Bromide | NaBr | 7647-15-6 |
| 14 | Polyacrylamide | PAM | 9003-5-8 |
| 15 | Sodium Molybdate | SUMO | 7631-95-0 |
| 16 | Sodium Tripolyphosphate | STPP | 7758-29-4 |
Water Treatment Chemicals supplier in your city nearby you in your COUNTRY INDIA, OMAN, UAE, NAIROBI
Sodium Molybdate Supplier in Dubai, Fujairah, Sharjah, Ajman, Abudhabi, Gulf MiddleEast, Mumbai, Kolkata, Chennai, Visakhapatnam, Kandla Surat Gujrat, Ruwi Barka Sohar Muscat Oman, Nairobi, Sudan Yemen
Safety Data (MSDS)

| Product Name | SODIUM MOLYBDATE AR DIHYDRATE |
| Part Number | RXSOL-60-6605-537 |
Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
Branch : Kandla, Mumbai , Chennai, Vizag, Kolkata, UAE , OMAN , CANADA and KENYA
| Phone | +91 22 20871200 - 1400 |
| Fax | +91 22 27612100 :::AOH :0091 9821214367 |
| mail@rxmarine.com | |
| Website | www.rxmraine.com |

| Chemical Name | CAS | EC number | Weight |
| SODIUM MOLYBDATE AR DIHYDRATE | 10102-40-6 | 231-551-7 | 99% |

| Classification of the substance or mixture |
Not a hazardous substance or mixture according to Regulation (EC) No 1272/2008.
prolonged or repeated exposureH336 May cause drowsiness or dizziness.
H361fd Suspected of damaging fertility. Suspected of damaging the
unborn child.
H373 May cause damage to organs (Central nervous system) through
prolonged or repeated exposure
|
| Label elements | Not a hazardous substance or mixture according to Regulation (EC) No 1272/2008. |
| Other hazards | This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher. |

| If inhaled | After inhalation: fresh air. |
| If swallowed | After swallowing: make victim drink water (two glasses at most). Consult doctor if feeling unwell. |
| Most important symptoms and effects, both acute and delaye | The most important known symptoms and effects are described in the labelling (see section 2.2) and/or in section 11 |
| Indication of any immediate medical attention and special treatment needed | No data available |

| Suitable extinguishing media | Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. |
| Unsuitable extinguishing media | For this substance/mixture no limitations of extinguishing agents are given. |
| Special hazards arising from the substance or mixture | Not combustible. Ambient fire may liberate hazardous vapours. |
| Further information | Suppress (knock down) gases/vapors/mists with a water spray jet. Prevent fire extinguishing water from contaminating surface water or the ground water system. |
| Advice for firefighters | In the event of fire, wear self-contained breathing apparatus. |

| Personal precautions, protective equipment and emergency procedures | Advice for non-emergency personnel: Avoid inhalation of dusts. Evacuate the danger area, observe emergency procedures, consult an expert. For personal protection see section 8. |
| Enviromental Precaution | Do not let product enter drains. |
|
Methods and materials for containment and cleaning |
Cover drains. Collect, bind, and pump off spills. Observe possible material restrictions (see sections 7 and 10). Take up dry. Dispose of properly. Clean up affected area. Avoid generation of dusts. |
| Reference to other sections | For For disposal see section 13. |

| Advice on safe handling | Work under hood. Do not inhale substance/mixture. |
| Advice on protection against fire and explosion | NA |
| Hygiene measures | Change contaminated clothing. Preventive skin protection recommended. Wash hands after working with substance. For precautions see section 2.2. |
| Precautions for safe handling | Advice on safe handling Work under hood. Do not inhale substance/mixture. Hygiene measures Change contaminated clothing. Preventive skin protection recommended. Wash hands after working with substance. For precautions see section 2.2. |
| Conditions for safe storage, including any incompatibilities | Storage conditions Tightly closed. Dry. Hygroscopic. |
| Storage conditions |
Tightly closed. Dry. Hygroscopic.
Hygroscopic.Tightly closed. Dry.
Hygroscopic.
|
| Storage conditions | Tightly closed. Dry. Hygroscopic. |
| Storage class | Storage class (TRGS 510): 13: Non Combustible Solids |
| Specific end use(s) | Apart from the uses mentioned in section 1.2 no other specific uses are stipulated |
| Handling |
NA |
| Advice on general occupational hygiene | NA |

| Occupational Exposure limit values | No data available |
| Biological limit values | No data available |
| Exposure controls | Personal protective equipment |
| Engineering Control | NA |
| Eye/face protection |
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses
government standards such as NIOSH (US) or EN 166(EU). Safety glassesUse equipment for eye protection tested and approved under appropriate
government standards such as NIOSH (US) or EN 166(EU). Safety glasses
|
| Body Protection | Protective clothing |
| Skin protection |
This recommendation applies only to the product stated in the safety data sheet,
supplied by us and for the designated use. When dissolving in or mixing with other
substances and under conditions deviating from those stated in EN374 please
contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell,
Internet: www.kcl.de). Full contact Material: Nitrile rubber Minimum layer thickness: 0,11 mm Break through time: 480 min Material tested:KCL 741 Dermatril® L This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de). Splash contact Material: Nitrile rubber Minimum layer thickness: 0,11 mm Break through time: 480 min Material tested:KCL 741 Dermatril® L
|
| Respiratory protection | Required when dusts are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter type: Filter type P3 The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented. |
| Other Protection Measure | NA |
| Control of environmental exposure | Do not let product enter drains. |
| Thermal hazards | No data available |
Gloves Suit

| Physical state | Crystalline |
| Colour | Colorless |
| Odour | Odorless |
| Odor Threshold | Not Applicable |
| pH | 5,74 at 430 g/l at 22,5 °C |
| Melting Point | Melting point/range: 755 °C - lit. |
| Boiling Point | 1.390 °C at ca.1.013 hPa |
| Flash Point | No data available |
| Viscosity |
Viscosity, kinematic: 2550 mm2/s - OPPTS 830.7100
Viscosity, dynamic: No data available
|
| Evaporation Rate | Not Applicable |
| Flammability (solid, gas) | The product is not flammable. - Flammability (solids) |
| Explosive limits | No Data Available |
| Upper/lower flammability or explosive limits | No data available |
| Autoignition temperature | No data available |
| Decomposition temperature | > 750 °C |
| Vapour pressure | 1 hPa at 806 °C |
| Density | 3,2 g/cm3 at 25 °C |
| Vapour Density | 1 hPa at 806 °C |
| Specific Gravity | No data available |
| Partition coefficient | No data available |
| Explosive properties | None |
| Solubility | 946 g/l at 25 °C - soluble |
| Ignition temperature | No information available. |
| Particle characteristics | No data available |
| Oxidizing properties | None |
| Other safety information | No data available |

| Reactivity | No data available |
| Stability | The product is chemically stable under standard ambient conditions (room temperature) . |
| Possibility of hazardous reactions | Risk of explosion with: Alkali metals halogen-halogen compounds Generates dangerous gases or fumes in contact with: Strong acids Release of: hydrogen bromide |
| Conditions to avoid |
Avoid moisture. Heat.
no information available
|
| Incompatible materials | No data available |
| Hazardous Polymerization | In the event of fire: see section 5 |

| Acute toxicity | LD50 Oral - Rat - male and female - 4.200 mg/kg (OECD Test Guideline 401) Inhalation: No data available LD50 Dermal - Rabbit - male and female - > 2.000 mg/kg (OECD Test Guideline 402) |
| Skin corrosion/irritation | Skin - Rabbit Result: No skin irritation - 4 h (US-EPA) |
|
Serious eye damage/eye irritation Eyes - Rabbit
Result: slight irritation
(US-EPA)
|
Eyes - Rabbit Result: slight irritation (US-EPA) |
| Respiratory or skin sensitization | Maximization Test - Guinea pig Result: negative (OECD Test Guideline 406) |
| Serious eye damage/eye irritation | Eyes - Rabbit Result: slight irritation (US-EPA) |
| Rout Of Entry | NA |
| Toxicity to Animal | NA |
| Toxic Effects on Human | NA |
| Germ cell mutagenicity |
Test Type: Ames test Test system: Salmonella typhimurium Metabolic activation: with and without metabolic activation Method: OECD Test Guideline 471 Result: negative. Test Type: Mutagenicity (mammal cell test): chromosome aberration. Test system: Human lymphocytes Metabolic activation: with and without metabolic activation Method: OECD Test Guideline 473 Result: negative Test Type: unscheduled DNA synthesis assay Test system: mammalian cells Metabolic activation: with and without metabolic activation Method: OECD Test Guideline 482
Result: negative Test Type: Micronucleus test Species: Mouse Cell type: Bone marrow Application Route: Oral Method: OECD Test Guideline 474 Result: negative Remarks: The value is given in analogy to the following substances: ammonium bromide
|
| Reproductive toxicity | Suspected of damaging fertility or the unborn child. |
| Specific target organ toxicity - single exposure | May cause drowsiness or dizziness. |
| Specific target organ toxicity - repeated exposure | May cause damage to organs through prolonged or repeated exposure.Central nervous system |
| Special Remarks on other Toxi Effects on Humans: |
NA |
| Additional Information | Endocrine disrupting properties |
| Assessment | The substance/mixture does not contain components considered to have endocrine disrupting properties according to REACH Article 57(f) or Commission Delegated regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605 at levels of 0.1% or higher. Repeated dose toxicity - Rat - male and female - Oral - NOAEL (No observed adverse effect level) - 100 mg/kg - LOAEL (Lowest observed adverse effect level) - 225 mg/kg Remarks: The value is given in analogy to the following substances: ammonium bromide RTECS: VZ3150000 Effects due to ingestion may include:, sedation To the best of our knowledge, the chemical, physical, and toxicological properties have not been thoroughly investigated Systemic effects:Tiredness After uptake of large quantities: ataxia (impaired locomotor coordination) confusion Convulsions Coma However, when the product is handled appropriately, hazardous effects are unlikely to occur. Handle in accordance with good industrial hygiene and safety practice. |
| Endocrine disrupting properties | Product: Assessment : The substance/mixture does not contain components considered to have endocrine disrupting properties according to REACH Article 57(f) or Commission Delegated regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605 at levels of 0.1% or higher. Repeated dose toxicity - Rat - male and female - Oral - NOAEL (No observed adverse effect level) - 100 mg/kg - LOAEL (Lowest observed adverse effect level) - 225 mg/kg Remarks: The value is given in analogy to the following substances: ammonium bromide RTECS: VZ3150000 Effects due to ingestion may include:, sedation To the best of our knowledge, the chemical, physical, and toxicological properties have not been thoroughly investigated. Systemic effects:Tiredness After uptake of large quantities:ataxia (impaired locomotor coordination) confusion Convulsions Coma However, when the product is handled appropriately, hazardous effects are unlikely to occur.Handle in accordance with good industrial hygiene and safety practice. |

| Persistence and degradability | No data available |
| Toxicity |
Toxicity to fish semi-static test LC50 - Fish - > 440 mg/l - 96 h (OECD Test Guideline 203) Toxicity to daphnia and other aquatic invertebrates static test NOEC - Daphnia magna (Water flea) - >= 1.000 mg/l - 48 h (US-EPA)
Toxicity to algae ErC50 - Skeletonema costatum (marine diatom) - > 440 mg/l - 72 h (OECD Test Guideline 201) Toxicity to bacteria static test EC50 - activated sludge - > 1.000 mg/l - 3 h (OECD Test Guideline 209) Toxicity to fish(Chronic toxicity) semi-static test NOEC - Poecilia reticulata (guppy) - 10 mg/l - 124 d Remarks: (ECHA) Toxicity to daphnia and other aquatic invertebrates(Chronic toxicity) semi-static test NOEC - Daphnia magna (Water flea) - 7,5 mg/l - 21 d Remarks: (ECHA)
|
| Bioaccumulative potential | Bioaccumulation - 7 d at 25 °C - 53,11 mg/l(sodium bromide) Bioconcentration factor (BCF): 0,23 |
| Toxicity to fish | Semi-static test LC50 - Fish - > 440 mg/l - 96 h (OECD Test Guideline 203) |
| Toxicity to daphnia and other aquatic invertebrates | Static test NOEC - Daphnia magna (Water flea) - >= 1.000 mg/l - 48 h (US-EPA) |
| Toxicity to algae |
ErC50 - Skeletonema costatum (marine diatom) - > 440 mg/l - 72 h
(OECD Test Guideline 201)
|
| Toxicity to bacteria | Static test EC50 - activated sludge - > 1.000 mg/l - 3 h (OECD Test Guideline 209) |
| Eco Toxicity | Not Available |
|
Toxicity to
fish(Chronic toxicity)
|
Semi-static test NOEC - Poecilia reticulata (guppy) - 10 mg/l - 124 d Remarks: (ECHA) |
|
Toxicity to daphnia
and other aquatic
invertebrates(Chronic
toxicity)
|
Semi-static test NOEC - Daphnia magna (Water flea) - 7,5 mg/l - 21 d
Remarks: (ECHA)
|
| COD and BOD 5 | Not Available |
| Products Biodegradation: | NA |
| Mobility in soil | No Information available |
| Results of PBT and vPvB assessment | This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher. |
| Endocrine disrupting properties | Product: Assessment : The substance/mixture does not contain components considered to have endocrine disrupting properties according to REACH Article 57(f) or Commission Delegated regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605 at levels of 0.1% or higher. |
| Assessment | The substance/mixture does not contain components considered to have endocrine disrupting properties according to REACH Article 57(f) or Commission Delegated regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605 at levels of 0.1% or higher. |
| Other adverse effects | No data available |

| Disposal methods | NA |
| Contaminated packaging | NA |
| Waste treatment Method |
See www.retrologistik.com for processes regarding the return of chemicals and
containers, or contact us there if you have further questions.
|

| UN number |
ADR/RID: - IMDG: - IATA: - |
| UN proper shipping name |
ADR/RID: Not dangerous goods IMDG: Not dangerous goods
IATA: Not dangerous goods
|
| Transport hazard class(es) |
ADR/RID: - IMDG: - IATA: - |
| Packaging group |
ADR/RID: - IMDG: - IATA: - |
| Environmental hazards |
ADR/RID: No IMDG Marine Pollutant: No IATA: No |
| Special precautions for user | No data available |
| Further information | Not classified as dangerous in the meaning of transport regulations. |
| Transport in bulk according to IMOinstruments | No data available |

| Safety, health and environmental regulations/legislation specific for the substance or mixture | This material safety data sheet complies with the requirements of Regulation (EC) No. 1907/2006. |
| Safety, health and environmental regulations specific for the product in question | NA |
| National legislation | NA |
| DSCL (EEC) | NA |
| Other regulations | Observe work restrictions regarding maternity protection in accordance to Dir 92/85/EEC or stricter national regulations where applicable. Take note of Dir 94/33/EC on the protection of young people at work |
| Chemical Safety Assessment | For this product a chemical safety assessment was not carried out |

| Other Information |
The information above is believed to be accurate and represents the best information currently available to us.However,we make no warranty of merchantability or any other warranty, express or implied, with respect to such information, and weassume no liability resulting from its use. Users should make their own investigations to determine the suitability of the information for their particular purposes. In no event shall be liable for any claims, losses, or damages of any third party or for lost profits or any special, indirect, incidental, consequential or exemplary damages, howsoever arising, even if Rx Marine International has been advised of the possibility of such damages.
DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.
|