AMERZAMINE

Part No: RXSOL-14-5005-554

100 percent water soluble and 100 percent Volatile corrosion inhibitor for Low Medium High Pressure Boiler Water System.

Category

100 percent water soluble and 100 percent Volatile corrosion inhibitor for Low Medium High Pressure Boiler Water System.
Corrosion Inhibitor for Boiler Neutralizer Concentrated liquid neutralising agent for corrosion control in condensate and feed water systems, contain blends of low, medium and high volatility amines that provide great protection and neutralization of acidic gases, such as CO2 throughout a condensate system. Protects boiler surfaces by forming an iron tannate film.
A liquid neutralizing amine used to control corrosion and pH in steam and condensate systems.

Application

Hydrazine Based oxygen scavenger and Corrosion inhibitor controls ferrous and non-ferrous corrosion in feedwater, boilers, steam, and condensate lines.


Corrosion Inhibitor for Boiler Neutralizer is a blend of volatile liquid / steam distributions ratios that neutralise the acid contaminants in condensate and feed water thus providing protection against acid corrosion in the complete system.The most common cause of acid corrosion in condensate and feed water systems is dissolved carbon dioxide. Condensate control neutralises this acid and maintains the condensate and feed water in an alkaline condition
Used in medium and high-pressure boilers including ultra high-pressure boilers.

Fields Of Application:-
Corrosion Inhibitor for Boiler Neutralizer is an effective neutralizing type corrosion inhibitor & oxygen scavanger  for steam condensation system. And can also be used to protect Boilers /Metals surfaces form corrosion.It removes oxygen efficiently in open feed systems and gives effective corrosion inhibition of boiler/exhaust gas economizer system surfaces . Its Chemical reaction by converting Fe2O3 (rust) to organic iron compound protect further IRON rust reaction .

Operating Process:-
RXSOL-CC72 neutralizes the acid components of feed water.The proportion of 
Corrosion Inhibitor for Boiler Neutralizer depends upon the Carbon dioxide content of the condensate. Basically Corrosion Inhibitor for Boiler Neutralizer neutralizes the acid contents & maintains the condensate and feed water in the alkaline condition.  It also protects copper based metals.

PRODUCT APPLICATION
Used as solvent, as an intermediate in making of dyes, pharmaceuticals, fragrances and as an insect pheromones.
Dose

AMERZAMINE Corrosion Inhibitor for Boiler Neutralizer condensate is tested for PH to determine the dosage level. The PH limits are 8.3 - 9.0 . For an average system e. g. 10-M3, the dosage is approximately 0.15 ltr / day .

The necessary amount of Corrosion Inhibitor for Boiler Neutralizer is required or injected as frequently as to maintain the pH of the condensate at the main condensate pump outlet between 8.6-9.5 .  The amines pass over with the steam and have the dual function of elevating the pH of the steam/condensate and putting a protective micro film on the system pipe work. Acidic condensate is the result of carbonic acid (H2CO3) being formed as CO2 is released in the steam.Condensate prevents corrosion by carbonic acid on live systems. Its filming properties also reduce corrosion on shut down lines, when moisture and oxygen are present.

Packing sizes
Specialised corrosion inhibitor for ferrous and non-ferrous Boiler Water System available in 25 Ltr and 210 Ltr Pack.
Industrial area

AMERZAMINE manufacturer and supplier in India UAE Oman. AMERZAMINE Boiler Condensate Corrosion Control chemical manufacturer supplier in India UAE Oman.


 


Other Brand
RXSOL PRODUCT NAME
RXSOL PRODUCT CODE 
Remarks
AMERZINE
AMERZAMINE
RXSOL-14-5005-554
CHEMICALS REQUIRED FOR BOILER WATER TREATMENTS. 100 percent water soluble and 100 percent Volatile corrosion inhibitor for Low Medium High Pressure Boiler Water System.
AGK 100
One Shot Universal Liquitreat 100
RXSOL-50-5001-025
CHEMICALS REQUIRED FOR BOILER WATER TREATMENTS. A one-step and one SHOT treatment to control the formation of rust and scale in boilers. Contains alkaline compounds, scale and corrosion inhibitors, oxygen scavengers and sludge conditioners
AMEROYAL
AMEROL Evaporator Treatment
RXSOL-60-6001-025
CHEMICALS REQUIRED FOR FWG  TREATMENTS. AMEROL Evaporator Treatment: Advanced Scale & Foam Control for Evaporators
DESCALE IT
Descaling Liquid
RXSOL-11-1008-025
CHEMICALS REQUIRED FOR CLEANING THE FWG PLATES. Hardness Scale Dissolving Chemicals resulting parts from OVER HEATING.
ENVIROCARE VTC 4000
BTC Zyme
RXSOL-15-1496-025
CHEMICALS REQUIRED FOR TOILETS CLEANING AS CANOT USE OTHER CHEMICALS. Unique biological active liquid formulation containing specialized bacterial strains, biodegradable low foaming chemical cleaners and anti foam agents.
ENVIROMATE 2000
Enviro 2000 Soft
RXSOL-20-3022-025
CHEMICALS REQUIRED FOR CLEANING. Advance general cleaner Degreaser suitable for PRESSURE washing equipment, Also have pleasant odour and safe to the persons handling it . Can be used as a multipurpose cleaner for tank or general cleaning and all types of cleaning and degreasing operations.
LIQUIDEWT
Engine Water Treatment DEWT
RXSOL-40-4010-025
CHEMICALS REQUIRED FOR HT  and  LT COOLING WATER SYSTEM. Multi-functional corrosion inhibitor for protecting recirculating cooling and heating water systems. RXSOL LIQUID EWT treatment is an excellent treatment for diesel engine primary and secondary cooling water. It is also ideally suited for use in chilled water systems.
LT SOOT RELEASE
50
KG
CHEMICALS REQUIRED FOR ME EXHAUST GAS BOILER SOOT FLUSHING.
 
 
Remarks / Precaution

Basic Boiler System Schematic

Below is a summary of problems associated with the common impurities in water and solutions to each problem.

List Of Problems Caused By Impurities In Water

Impurity (Chemical Formula)

Problems

Common Chemical Treatment Methods

Alkalinity (HCO3-, CO32- and CaCO3)

Carryover of feedwater into steam, produce CO2 in steam leading to formation of carbonic acid (acid attack)

Neutralizing amines, filming amines, combination of both, and lime-soda.

Hardness (calcium and magnesium salts, CaCO3)

Primary source of scale in heat exchange equipment

Lime softening, phosphate, chelates and polymers

Iron (Fe3+ and Fe2+)

Causes boiler and water line deposits

Phosphate, chelates and polymers

Oxygen (O2)

Corrosion of water lines, boiler, return lines, heat exchanger equipments, etc. (oxygen attack)

Oxygen scavengers, filming amines and deaeration

pH

Corrosion occurs when pH drops below 8.5

pH can be lowered by addition of acids and increased by addition of alkalies

Hydrogen Sulfide (H2S)

Corrosion

Chlorination

Silica (SiO2)

Scale in boilers and cooling water systems

Lime softening

Note

Why AMERZAMINE corrosion inhibitor is important for Boiler System?
AMERZAMINE corrosion inhibitor form protective oxide films and passivates metal surfaces.

  • Easy to use liquid treatment.
  • Neutralizes the acids occurring in the condensate system.
  • Less maintenance required. Lower operating costs and increased reliability.

Safety Data (MSDS)

Product Name : RXSOL-14-5005-554
Product Type : AMERZAMINE

Company Details:

RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA

Stock Point : Mumbai, Kandla, Kolkata, Visakhapatanm - Gangavaram, Chennai - Ennore, Fujairah

Phone : +91 22 27815540 / 41 / 42
Fax : +91 22 2781 1318 :::AOH :0091 9821214367
Email : mail@rxmarine.com

Chemical Name

Concentration

CAS Number

EC Number

R Phrases*

Symbols

2-Amino Ethanol

5-10

141-43-5

205-483-3

20, 36/37/38

Xn

2-Diethyl Amino Ethanol

1-10

100-37-8

202-845-2

10, 20/21/22, 34

C
 

Dioctylamine C16H35N 5-9 7681-52-9 1120-48-5    

Propreitory Ingredients including Hydrazine

60-100

-

-

-

-

Corrosive

Corrosive

Odour

Slight smell of ammonia.

Appearance

Liquid, pale yellow, soluble in water.

Contact with eyes

Vapours or aerosols may cause irritation of eyes, nose and respiratory tract

Contact with skin

May cause redness and irritation.

Inhalation

Vapours or aerosols may cause irritation of eyes, nose and respiratory tract.

Ingestion

Not regarded as a potential route of exposure., In cases of severe exposure,Gastro-intestinal disturbances may develop.

Contact with skin

Remove contaminated clothing immediately and drench affected skin with plenty of water. Then wash with soap and water.When in doubt or symptoms persist, seek medical attention Contaminated clothing should be laundered before reuse

Contact with eyes

If substance has got into eyes, immediately wash out with plenty of water for at least 15 minutes.Seek medical advice

Ingestion

Do not induce vomiting.Never give anything by mouth to an unconscious person.Give 200-300mls (half pint) water to drink.Seek immediate medical attention

Inhalation

Remove patient to fresh air.Seek medical attention if ill effects occur

General

In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible) (S45)

Flammability                                                  May be combustible at high temperature.
Suitable extinguishing media  Foam Carbon dioxide (CO2) Dry powder.
Unsuitable extinguishing media For this substance/mixture no limitations of extinguishing agents are given.
Special hazards arising from the substance or mixture  Carbon oxides Nitrogen oxides (NOx) Combustible. Vapors are heavier than air and may spread along floors. Forms explosive mixtures with air on intense heating. Development of hazardous combustion gases or vapours possible in the event of fire.
Further information Suppress (knock down) gases/vapors/mists with a water spray jet. Prevent fire extinguishing water from contaminating surface water or the ground water system
Hazardous combustion
products
No data available
Advice for firefighters Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing
Protective Equipment No data available
Specific Hazards Arising from the Chemical No data available

Personal precautions, protective equipment and emergency procedures Advice for non-emergency personnel: Avoid generation and inhalation of dusts in all circumstances. Avoid substance contact. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert. For personal protection see section 8
Personal Protection Advice for non-emergency personnel: Avoid inhalation of dusts. Evacuate the danger area, observe emergency procedures, consult an expert. Advice for emergency responders: Protective equipment see section 8.
Enviromental Precaution Do not let product enter drains.
Methods and materials for
containment and cleaning
Cover drains. Collect, bind, and pump off spills. Observe possible material restrictions (see sections 7 and 10). Take up carefully. Dispose of properly. Clean up affected area. Avoid generation of dusts.
Reference to other sections    For disposal see section 13.


Advice on safe handling For precautions see section 2.2.
Incompatible materials  Keep away from alkalis, strong oxidizing agents and metals. Provide containment walls of adequate capacity to hold any accidental spills. 
Hygiene measures Immediately change contaminated clothing. Apply preventive skin protection. Wash hands and face after working with substance. For precautions see section 2.2.
Advice on    safe handling No data available
Conditions for safe storage, including any incompatibilities  Storage conditions No metal containers. Tightly closed. Do not store near acids. Storage stabilityRecommended storage temperature
Storage conditions Tightly closed.
Storage class Storage class (TRGS 510): 8A: Combustible, corrosive hazardous materials
Specific end     use(s) Storage class (TRGS 510): 8A: Combustible, corrosive hazardous materials
Advice on general occupational hygiene No data available
 


 

Exposure controls  Ingredients with workplace control parameters. 
Engineering Control Personal protective equipmen
Eye/face protection Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Tightly fitting safety goggles
Body Protection Protective clothing
Skin protection required
Respiratory protection
Required when vapours/aerosols are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter type: Filter type ABEK The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
Other Protection  Measure Handle in accordance with good industrial hygiene and safety practice.
Control of    environmental exposure Do not let product enter drains.
 

goggles                  gloves                suit               respirator

Goggles                   Gloves                        Suit                   Respirator

Odour

Slight smell of ammonia

Appearance

Liquid, pale yellow, soluble in water

PH

11.5 - 12.5 at 100 % concentration, pH 10 at 1 % concentration

Boiling point

~ 100 °C at 760 mm /Hg

Vapour pressure

not known

Vapour density

not known

Freezing point

~ 0 °C at 760 mm/Hg

Completely soluble in water

Specific gravity (water=1)

1.0

Not flammable

Reactivity                        Forms explosive mixtures with air on intense heating. A range from approx. 15 Kelvin below the flash point is to be rated as critical
Chemical stability The product is chemically stable under standard ambient conditions (room temperature)
Possibility of hazardous reactions No data available
Conditions to avoid Strong heating.                                                                            
Incompatible materials
Strong acids
Hazardous decomposition products In the event of fire: see section 5
 

Toxicological information

LD50 (oral,rat) 2100 mg/kg.( 2-Aminoethanol).LD50 (oral,rat) 1320 mg/kg.( 2-Diethylaminoethanol)

Inhalation

In cases of severe exposure, irritation may develop

Contact with skin

Causes irritation

Contact with eyes

Causes redness and irritation

Ingestion

The ingestion of significant quantities may cause gastro-intestinal disturbances

Carcinogenicity

No evidence of carcinogenic effects


 

Persistence and degradability Biodegradability
Toxicity to fish  Toxicity to fish LC50 - Danio rerio (zebra fish) - 0,54 mg/l - 96,0 h
Toxicity to daphnia and other aquatic invertebrates No data available
Toxicity No data available
Toxicity to bacteria  No data available
Toxicity to algae No data available)
Products Biodegradation No data available
Mobility in soil No data available
Results of PBT and vPvB assessment This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.
Endocrine disrupting       properties The substance/mixture does not contain components considered to have endocrine disrupting properties according to REACH Article 57(f) or Commission Delegated regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605 at levels of 0.1% or higher.
Other adverse effects No data available
 

Ecotoxicity

This product does not contain ingredients which are classified in the EU as dangerous for the environment.

Mobility

Completely soluble in water

Persistence and Biodegradability

The components in this product are readily biodegradable.

Bioaccumulation Potential

Bioaccumulation of the components in this product is insignificant.

Other Adverse Effects

No environmental problems are expected when the product is used / handled correctly . In its intended use, the product will not be released into the environment.Presents little or no hazard to the aquatic environment.

Classification

EU Waste class: 07.01

Disposal considerations

Do not discharge into drains or the environment, dispose to an authorised waste collection point. Disposal should be in accordance with local, state or national legislation

-  Not classified as hazardous for transport

Risk Phrases

Irritating to eyes, respiratory system and skin (R36/37/38)

Safety Phrases

In case of contact with eyes, rinse immediately with plenty of water and seek medical advice (S26).Wear suitable gloves and eye/face protection (S37/39)

Text  of  R  and  S  phrase  codes  used  In   this  safety  data  sheet :- R10: Flammable;  R20 : Harmful   by inhalation; 
R20/21/22: Harmfulby  inhalation,  in  contact  with  skin  and  if  swallowed;
R34: Causes burns;
R36/37/38: Irritating  to eyes,  respiratory  system  and  skin.The  information  provided about  the  product  on t his Safety Data Sheet has been
compiled   from  knowledge   of the   individual  constituents. Thedata  given  here is  based   on current  knowledge and experience .
This  Safety Data  Sheet  describes  the  productIn  terms   of  safety   requirements   and  does  not   signify  any  warranty  with  regard 
to the product's  properties The  data  given here only applies  when  product used for proper application(s).The product is not sold as suitable 
For  othe r applications - usage in such may cause risks not mentioned  in  this  sheet. 
Do  not  use  for other application(s) without seeking advice from manufacturer.
This Safety Data Sheet is provided in compliance with The Dangerous Substances Directive (67/548/EEC)
This Safety Data Sheet is provided in compliance with The Dangerous Preparations Directive (88/379/EEC)
This Safety Data Sheet is provided in compliance with The Safety Data Sheets Directive (2001/58EC)

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.

Flammability                                                  May be combustible at high temperature.
Suitable extinguishing media  Foam Carbon dioxide (CO2) Dry powder.
Unsuitable extinguishing media For this substance/mixture no limitations of extinguishing agents are given.
Special hazards arising from the substance or mixture  Carbon oxides Nitrogen oxides (NOx) Combustible. Vapors are heavier than air and may spread along floors. Forms explosive mixtures with air on intense heating. Development of hazardous combustion gases or vapours possible in the event of fire.
Further information Suppress (knock down) gases/vapors/mists with a water spray jet. Prevent fire extinguishing water from contaminating surface water or the ground water system
Hazardous combustion
products
No data available
Advice for firefighters Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing
Protective Equipment No data available
Specific Hazards Arising from the Chemical No data available