C SHINE Alkaline Coil Cleaner

Part No: RXSOL-39-1668-005

Alkaline-based ceaner with a strong foaming action designed to rapidly emulsify greasy soils and oxidation…thereby leaving coils dirt-free and shining. suitable product for cleaning air-cooled condensers, permanent filters and other finned heating

C SHINE Alkaline Coil Cleaner

Heavy-Duty Alkaline Cleaner for HVAC, Air-Conditioning & Industrial Coils

C SHINE Alkaline Coil Cleaner is a concentrated alkaline cleaning chemical formulated for removing grease, oil, dirt, dust, carbon deposits and other stubborn contaminants from air-conditioning and industrial heat-transfer surfaces.

It is suitable for cleaning condenser coils, evaporator coils, HVAC coils, air-cooled equipment, ventilation systems and industrial heat exchangers, helping restore clean heat-transfer surfaces and maintain efficient equipment operation.

Product Name: C SHINE Alkaline Coil Cleaner
Product Type: Alkaline Coil & Heat-Transfer Surface Cleaner
Physical Form: Liquid
Application: HVAC, AC Coils, Condenser Coils, Evaporator Coils, Industrial Equipment
Brand: Muscat Chemical / RXSOL
Supply Location: Muscat, Oman

Alkaline Coiler Cleaner for AC units, Coils non-acid coil cleaners developed to provide foaming and brightening capabilities comparable to acid-based coil cleaners without the dangers of strong acids for cleaning of Air coolers, Scavenging air systems and turbochargers of diesel engine.

  1. Excellent grease-cutting capability.
  2. High foaming action-penetrates deep into multi-row coils to foam out dirt,grease and grime.
  3. One step cleaner-cleans,brightens and deodorizes.
Application

Applications

HVAC & Air-Conditioning Systems

C SHINE Alkaline Coil Cleaner can be used for maintenance cleaning of:

  • Air-conditioner condenser coils

  • Evaporator coils

  • Air-cooled condensers

  • HVAC cooling coils

  • Ventilation equipment

  • Fan-coil units

  • Heat-transfer surfaces

  • Commercial and industrial AC systems

Industrial Cleaning

The product can also be considered for cleaning suitable industrial equipment contaminated with:

  • Grease

  • Oil

  • Dust

  • Atmospheric dirt

  • Carbonaceous deposits

  • Organic contamination

  • General industrial grime

Marine Applications

C SHINE may also be useful for suitable marine HVAC and machinery-maintenance applications, including cleaning external heat-transfer surfaces and air-conditioning equipment.

Dose

Using Procedure


Method Dilution / Concentration Application Steps Notes / Precautions
In-Service Cleaning Undiluted or as per system specs Pass through air trunking upstream of the charge air cooler. Follow with clean water rinse. Use proper dosing and injection system. Ensure thorough rinse.
Typical Cleaning (Spray) 1 part cleaner to 1–3 parts water Apply using low-pressure sprayer. Leave for 3–7 minutes. Rinse thoroughly with water to remove all foam. Remove all residues from roofs or surfaces to avoid deterioration. Fumes may cause irritation indoors.
Air Cooler / Turbocharger Cleaning 5–25% in water Inject cleaning solution for 10–15 minutes. Follow with equal quantity of fresh water for rinsing. Ensure engine is off. Proper drainage required during the process.
Hand Spray Cleaning Use concentrate Spray directly on coils. Allow at least 1 hour for penetration. Rinse with high-pressure water. Keep drain valve open during cleaning. Close after flushing. Engine must remain off.
Soak Method Concentrated solution Dip parts in solution. Allow time for deposits to loosen. Rinse thoroughly. Ideal for stubborn carbon on metal machine parts. Wear protective gloves and goggles.

Typical Cleaning Procedure

  1. Switch off and isolate the equipment before cleaning.

  2. Remove loose dust and debris from the coil surface.

  3. Apply the C SHINE cleaning solution according to the current product instructions.

  4. Allow suitable contact time for the cleaner to penetrate deposits.

  5. Agitate heavily contaminated areas where required.

  6. Rinse thoroughly with clean water.

  7. Inspect the coil and repeat cleaning where necessary.

  8. Allow the equipment to drain and dry before returning it to service.

Important: Exact dilution, contact time and application temperature should be selected according to the current RXSOL/Muscat Chemical TDS and the condition/material of the coil.

Suitable Cleaning Areas

C SHINE Alkaline Coil Cleaner can be used for suitable:

  • Copper coils

  • Aluminum coil assemblies

  • HVAC equipment

  • Air-conditioning units

  • Condenser assemblies

  • Evaporator assemblies

  • Industrial cooling equipment

  • Heat-transfer equipment

Material compatibility should always be confirmed before full-scale application, particularly on aluminum, galvanized surfaces, coatings, painted components and mixed-metal assemblies.

Precaution ::--
Avoid skin / eye contact. Wear gloves and goggles when using. Use in well ventilated areas. Do not breathe vapors.

Technical specifications
Appearance Clear, Slight Yellow
Odor Fresh
pH Alkaline
Sp. Gravity >1.15

Key Features

  • Heavy-duty alkaline cleaning action

  • Removes accumulated grease and oily deposits

  • Helps loosen dirt, dust and carbonaceous contamination

  • Suitable for condenser and evaporator coil cleaning

  • Useful for HVAC and air-conditioning maintenance

  • Helps improve cleanliness of heat-transfer surfaces

  • Suitable for industrial and marine maintenance applications

  • Can be applied by spray, brush or suitable cleaning equipment

  • Designed for professional maintenance and cleaning operations

Remarks / Precaution

Why Customers prefer Alkaline Coil Shine Coiler Cleaner Non Acid?


  • Reduce air-conditioning cost  by allowing air-conditioning systems and units to run at maximum efficiency , Saves energy costs
  • A proper regular maintenance program including the use can substantially lengthen condenser life and save equipment replacement and downtime.
  • Cuts quickly through oily grime and Industrial air-borne impurities to restore condenser coils.
  • Due to its high penetration effect ,  Agitation or Scrubbing doesn't require
  • Simple spray on off operation to restores dirty condenser coils to peak efficiency
Note

Characteristics


  • Formulated to remove oil,grease & carbon deposits from air coolers & scavenging system
  • Efficient and economical
  • Renders surfaces oil-repellent
  • Maintains and stabilizes air cooler efficiency at maximum
  • Saves time, maintenance costs and avoids risks of damage when dismantling
  • Leaves no residue and has no harmful effect on engine
  • Product in water solution is non-flammable, non-explosive and has no flash point
  • Can be used for light carbon removal from machinery parts

Safety Data (MSDS)

 

Product Name : RXSOL-39-1668-005
Product Type : C SHINE Alkaline Coil Cleaner

Company Details:

RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA

Stock Point: Mumbai, Kandla, Kolkata, Vishakhapatnam, Chennai, Fujairah, Muscat Barka, Nairobi Kenya, Canada

Phone : +91 22 65113333 / 5555 / 9999 / 27611360
Fax : +91 22 2781 1318 :::AOH :0091 9821214367
Email : mail@rxmarine.com

 

Ingredients CAS %
Proprietory silicate compound - >60
Ethoxylatednonylphenol 9016-45-9 5-7
Alkalline Agent - 10-15
Disodium Metasilicate 6834-92-0 4-6
Sodium Dodecylbenzenesulfonate 25155-30-0 3-5
dipropylene glycol monomethyl ether 34590-94-8 3-5

Irritating eyes possible redness and burns. Prolonged contact with skin cause sever burns.
Breath to spray mist can be
Irritation, If spill can causes slippery floor.

Skin Corrosive, possible redness at point Remove contaminated clothing. Immediately wash
contact and may cause sever burns of excess chemical with plenty soap and water. apply
prolonged contact. emollient cream. Obtain medical attention
Eyes Corrosive, stinging with some redness irrigate immediately with plenty of water. Continue
Possible cause corneal burns irrigation for at least 10 to 15 minutes. seek medical attention immediately
Ingestion Corrosive, Nausea, vomiting and stomach Do not induce vomiting which may contaminate the
upset and pain occur lungs. If unconscious do not give anything by mouth.if necessary give artificial respiratory. If conscious give one pint of water to drink. Obtain medical attention  immediately
Inhalation  Inhalation of air mist during spray may Remove to fresh air. Rest, treat symptomatically,
cause irritation of mucous membranes seek medical advice immediately.

 

 

Extinguishing Media Product is non flammable
Special Protective Equipment Wear breathing apparatus and full protective clothing. Keep container cool
by spraying with water if exposed to fire
Exposure Hazards None

 

Do not allow entry into drain, sewers and water courses. Mop up with absorbent material such as sand or earth.
Scrap or shovel up and transfer to a suitable container. Clean up affected area with plenty of water Prevent slip
hazards. See ‘Disposal Consideration’  

Store in original container. Store separately from strong oxidising agents. Avoid contact with skin, eyes and clothing.

Keep out reach of children.
  

WEL= Workplace Exposure Limits PROTECTIVE EQUIPMENT:-

 

Engineering Measures Provide sufficient ventilation during operations which cause vapour formation.
Hands Protection Use suitable protective gloves if risk of skin contact.
Eyes Protection Wear approved safety goggle.
Other Protection Wear appropriate clothing, respiratory to prevent any possibility of inhalation.
Hygiene Measures Make eyes wash & showering accessible, wash at the end of each work shift and before eating, smoking using the toilet.

 

Appearance : Clear brownish liquid
Odour :  NA
pH : Alkaline
Flash point : 100°C and above
Flammability : Non-flammable
Auto-flammability : Not determined
Relative density : 1.1 +/- 0.1
Solubility : Soluble in water Complete

Stability Stable
Conditions to Avoid Mixtures of acids, isocyanates, rapid addition to hot water. Will catalyze reacting of
other chemicals
Incompatibility Strong acids
Hazardous decomposition
products:
Non
Hazardous polymerization Will not occur

Keep away from strong oxidising agent. (React with material): aluminum and their alloys, zinc and galvanise)
 

Corrosive, contact with eyes may cause to irritation and burns. Stinging and redness to skin, prolonged and repeated cause sever burns.
Inhalation breath to spray mist may sting to mucous membranes and/or cough and a sore throat.
The nature and severity of the acute effects precludes the likelihood of chronic exposure.
 

Biodegradability: Not Applicable Chemical Oxygen Demand ( mg.02/1): Not determined Aquatic toxicity studies have not been conducted

on this product.
 

Recycle used containers if facilities are available, if not incineration is recommended. Failing this, use landfill.
Be sure to comply with local authority regulation.
 

 

Proper Shipping Name : Pottasium Hydroxide, Solution  
UN Number : 1284  
ICAO-Air : Class 8 Packaging group III
IMO Sea : Class 8 Packaging group III
ADR Road : Class 8 Packaging group III

Supply classification: Corrosive Hazard pictogram: Risk phrases: R35 Causes sever burns R43 May cause sensitisation by skin contact.
Safety phrases: S24/25 Avoid contact with skin and eyes Corrosive S26 Incase of contact with eyes, rinse immediately with plenty of water
and seek medical advice
S27 Take off immediately all contaminated clothing
S28 After contact with skin, wash immediately with plenty water
S37/39 Wear suitable gloves and eye/face protection.
 

Data from the following sources have been used to compile this document.
HSE – EH40/93 Occupational exposure limits
HSE – EH29/93 Occupational skin diseases; Health and Safety Precaution
HSC – Safety Data Sheets for substances and preparation dangerous for supply.
Date of issue: 31.08.2010
 

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.