Part No: RXSOL-50-5002-025
Alkalinity Builder Very usefull Concentrated Alkaline Liquid For Maintaining Ph which protects corrosion, scalling by controlling Calcium scale in water system.
RXSOL Alkalinity Control – Boiler Water Treatment Chemical
Boiler Water pH Controller | Alkalinity Booster | Boiler Corrosion Prevention | Marine & Industrial Boiler Treatment
Brand: RXSOL – RX Marine International
Product Name: RXSOL Alkalinity Control
Product Category: Boiler Water Treatment Chemicals
Chemical Type: Alkaline Boiler Water Conditioning Agent
Applications: Marine Boilers, Auxiliary Boilers, Industrial Steam Boilers and Boiler Feedwater Systems
Product Description
RXSOL Alkalinity Control is a concentrated alkaline boiler water treatment chemical designed to maintain the required alkalinity and pH in marine and industrial boiler systems.
Proper boiler water alkalinity is essential for controlling corrosion, maintaining effective phosphate treatment and supporting efficient steam generation.
During boiler operation, variations in feedwater quality, condensate return and makeup water composition can cause fluctuations in boiler water alkalinity. Insufficient alkalinity may increase the risk of corrosion, while excessive alkalinity can contribute to foaming, carryover and caustic-related damage.
RXSOL Alkalinity Control is intended to maintain the required alkaline conditions within the boiler, helping protect internal metal surfaces and supporting reliable boiler operation.
The product is suitable for use as part of a comprehensive boiler water treatment program incorporating oxygen scavengers, phosphate treatment, sludge conditioners and routine water analysis.
Boiler Water Treatment Chemicals Concentrated liquid alkaline product for corrosion and Calcium scale control in boilers. Very usefull Concentrated Alkaline Liquid For Maintaining Ph - To adjust alkalinity.
Suitable for Low-pressure boiler systems (0-32 bar) , medium-pressure steam propulsion vessels (32-60 bar). And also suitable to used for high pressure steam generating systems (60-84 bar).
Mechanism : It converts calcium hardness into soft, non-adherent sludge that is easily removed by blowdown.
Applications
1. Marine Boiler Water Treatment
RXSOL Alkalinity Control is intended for maintaining suitable boiler water alkalinity in marine auxiliary boilers and other approved shipboard steam-generating systems.
2. Industrial Steam Boilers
Used in boiler treatment programs for industrial plants, manufacturing facilities and process steam applications.
3. Boiler Water pH Adjustment
Helps correct insufficient boiler water alkalinity, according to water analysis and the boiler manufacturer's recommended control limits.
4. Boiler Corrosion Control
Supports corrosion management by maintaining suitable alkaline conditions on internal boiler surfaces.
5. Phosphate Boiler Treatment Programs
Can be used alongside compatible phosphate-based boiler treatment chemicals where separate alkalinity adjustment is required.
6. Boiler Water Conditioning
Helps maintain appropriate water chemistry during routine boiler operation, subject to proper monitoring and blowdown control.
RXSOL-50-5002-025 provides the alkaline condition for hardness control to function correctly. Without the correct precipitation and subsequent blow down of hardness salt, scale would form. This would result in restriction in water flow, ineffective heat transfer and local corrosion. The end effect would be an inefficient boiler and ultimately component failure. RXSOL-50-5002-025 also provides the alkaline condition required for corrosion control, by neutralization of acidic gases
For optimum results dose RXSOL-50-5002-025 direct to the boiler with a RXSOL Boiler Water Treatment Dosing unit, or via the bypass pot- feeder installed in the boiler feed line.
Required dosage can be controlled by pH & alkalinity test dosage chart .
1 milliliter of RXSOL-50-5002-025 concentrated alkaline liquid per ton of distilled water provides 0.5 ppm of lkalinity hydrate.
Low-pressure boiler (up to 28 bars)
Add RXSOL-50-002-025 to 5 litre in feed – water, There is no any specific method can be passed through the recalculating or the main feed pipe into the stream or the hot well tank.
High – Pressure Boiler (28 to 60 bars)
Dissolve the desired volume of RXSOL-50-002-025 to 5 ltr of feed – water, which should then be passed into the stream or water drum through the chemical pump.
Note:- It can also be used as a neutralizing agent following acid cleaning with descaling materials ( RXSOL-11-1008--DC descaling Liq / RXSOL-54-1008-SA Safe Acid PWD )
Recommended Dosage and Application
Dosage must be determined from actual boiler water alkalinity, system volume, operating pressure, feedwater quality and the concentration of the supplied RXSOL formulation.
Unlike general-purpose detergents, boiler alkalinity control chemicals should not be dosed using a fixed universal percentage.
General Dosing Procedure
-
Collect a representative boiler water sample using an approved cooled sampling arrangement.
-
Measure boiler water pH, P-alkalinity, M-alkalinity and conductivity.
-
Compare the results with the boiler manufacturer's recommended operating limits.
-
Calculate the required chemical addition based on the alkalinity deficit and product concentration.
-
Introduce the product through an approved chemical dosing system.
-
Allow adequate circulation and mixing.
-
Retest boiler water and adjust dosing gradually.
-
Maintain routine monitoring and appropriate boiler blowdown.
Example: Alkalinity Adjustment Calculation
For a hypothetical boiler containing 10,000 litres of water, assume the treatment program requires an additional 100 mg/L of hydroxide alkalinity expressed as CaCO₃.
The theoretical pure NaOH requirement is:
For a hypothetical 25% w/w sodium hydroxide solution:
This calculation assumes that the entire specified increase is attributable to sodium hydroxide, with no buffering or competing reactions. It is an illustration only, not a recommended field dose. Actual treatment requires analysis of the boiler water chemistry and verified product concentration.
Testing control procedure
- Test water sample from the water boiler as described in the direction of the Alkalinity Test Kit ( p & m Total ) http://www.rxmarine.com/Alkalinity-test-kit
- Determine the present alkalinity value expressed as ppm CaCO3 .
- Desired level of 100-150 ppm as CaCO3.
- A control test for the alkalinity of the water should be conducted after 3- 6 hours from the application.
Technical Specifications
|
Parameter |
Typical / Proposed Specification |
|---|---|
|
Product Name |
RXSOL Alkalinity Control |
|
Appearance |
Clear liquid |
|
Colour |
Colourless to pale yellow |
|
Chemical Base |
Alkaline hydroxide-based formulation |
|
pH (Concentrate) |
Strongly alkaline |
|
Water Solubility |
Miscible with water |
|
Primary Function |
Boiler Water Alkalinity Adjustment |
|
Secondary Function |
Boiler Water pH Control |
|
Application |
Marine and Industrial Boilers |
|
Dosing Method |
Controlled chemical dosing |
|
Packing |
25 L, 210 L and 1,000 L, subject to availability |
These are proposed characteristics of an alkaline boiler treatment formulation. Actual RXSOL specifications, product code, hydroxide concentration, density and packaging must be confirmed from the approved TDS and batch COA.
Boiler Water Treatment Chemicals Alkalinity Control manufacturer and supplier in India UAE Oman, Alkalinity Control is most valuable Boiler water Treatment chemicals to converts calcium hardness into soft, non-adherent sludge that is easily removed by blowdown. Alkalinity controller boiler chemical manufacturer and supplier in Mumbai, Chennai, Kolkata, Visakhapatnam, Surat, Gandhidham, Chennai Ennore, Paradip, Nashisk, Pune, Varanashi, Patna, Tata, Ranchi, Fujairah, Sharjah, Ajman, Abudhabi, Dubai, UAE Gulf, Barka, Ruwi Ghala, Muscat Oman, Nairobi, Kenya, Canada
Alkalinity control makes sludge in soft form, which can be easily blown down from bottom side of BOILER.
Equivalent Product Other valuable peer company product :
| Nalco 22372 | RXSOL-50-5020-025 | Boiler Water Treatment Auto |
| Nalco3DT- 465 | RXSOL-40-4091-025 | Scale and Corrosion Inhibitor for Cooling Water |
| Nalco ST 40 | Rxsol-40-4009-025 | MICRO BIOCIDE Cooling Water |
| Nalco 77224 | RXSOL-50-5002-025 | Alkalinity Control |
| Nalcool 2000 | RXSOL-40-2000-025 | RXSOL 2000 Corrosion Inhibitor |
| Nalco ST40 | RXSOL-40-4009-025 | MICRO BIOCIDE Cooling Water |
| Nalco 404 | RXSOL-50-5021-025 | Hardness Control Liquid |
Frequently Asked Questions
Q1. What is RXSOL Alkalinity Control used for?
It is intended for adjusting and maintaining alkalinity in marine and industrial boiler water systems.
Q2. Why is alkalinity important in boiler water?
Correct alkalinity helps control corrosion and supports stable boiler water treatment chemistry.
Q3. Can low boiler water alkalinity cause corrosion?
Yes. Insufficient alkalinity may increase the risk of acidic corrosion, depending on operating conditions and water chemistry.
Q4. Can excessive alkalinity damage boilers?
Yes. Excessive alkalinity can contribute to foaming, steam carryover and caustic-related damage.
Q5. Is RXSOL Alkalinity Control an oxygen scavenger?
No. Alkalinity adjustment and dissolved oxygen removal are separate treatment functions.
Q6. Can the product be used with phosphate boiler treatment?
It may be used alongside a compatible phosphate treatment program where separate alkalinity adjustment is necessary.
Q7. How much RXSOL Alkalinity Control should be added?
The dose depends on the measured alkalinity deficit, boiler water volume, operating conditions and actual product concentration.
Q8. Is the product suitable for high-pressure boilers?
Suitability depends on the boiler pressure, manufacturer requirements and the verified formulation. High-pressure systems often require more restrictive water chemistry controls.
Q9. What is RXSOL ALCA SOLUTION used for?
It is intended to raise and maintain boiler water alkalinity and pH.
Q10. Can it prevent boiler corrosion?
Maintaining proper alkalinity helps reduce corrosion caused by acidic boiler water, but complete corrosion control also requires appropriate oxygen control and overall water chemistry management.
Q11. Can it be used with oxygen scavengers?
It may be incorporated into a boiler treatment programme containing a compatible oxygen scavenger. Concentrated products should not be mixed directly unless compatibility has been confirmed.
Q12. Is ALCA SOLUTION the same as a condensate neutralizing amine?
No. ALCA SOLUTION is intended primarily for boiler water alkalinity control. Neutralizing amines are used mainly to control pH and carbonic acid corrosion in steam and condensate systems.
Q13. What is the recommended dosage?
Dosage depends on the chemical concentration, boiler water analysis and operating requirements. A product-specific dosage cannot be established without these details.
RXSOL Boiler Water Treatment Chemical Supplier in India, UAE and Oman
RXSOL supplies marine and industrial boiler water treatment chemicals for shipping companies, shipyards, power plants and industrial maintenance operations.
India: Mumbai, Kandla, Mundra, Hazira, Kolkata, Haldia, Chennai, Ennore, Visakhapatnam, Kakinada, Paradip and other industrial centres.
United Arab Emirates: Dubai, Fujairah, Sharjah, Abu Dhabi, Jebel Ali and Ruwais.
Oman: Muscat, Sohar, Salalah and Duqm.
Other Markets: Qatar, Saudi Arabia and international shipping destinations, subject to availability and delivery arrangements.
RXSOL Alkalinity Control – Manufacturer, Supplier and Exporter
RXSOL provides boiler water treatment chemicals for marine auxiliary boilers, industrial steam generators and water treatment service providers.
Our boiler treatment portfolio includes alkalinity control agents, phosphate treatments, oxygen scavengers, sludge conditioners and condensate treatment chemicals.
For product specifications, dosing recommendations, SDS, COA, packing and bulk supply enquiries, contact the RXSOL technical sales team.
Product Details
|
Product Element |
Product Content |
|---|---|
|
Product Title |
Alkalinity Control Boiler Water Treatment Chemical – RXSOL |
|
Product Description |
RXSOL Alkalinity Control boiler water treatment chemical for pH adjustment, corrosion control and alkalinity management in marine and industrial boilers. |
|
Product Keyword |
Alkalinity Control Boiler Water Treatment Chemical |
|
Product SET |
|
|
Product Keywords |
Boiler Water Alkalinity Booster, Boiler pH Controller, Marine Boiler Water Treatment, Boiler Corrosion Inhibitor, Hydroxide Alkalinity Control, Industrial Boiler Treatment Chemical |
|
Suggested Field |
RXSOL Alkalinity Control – Marine & Industrial Boiler Water Treatment Chemical |
Technical note: The product code and actual composition have not been provided. Before publishing this as a certified RXSOL technical data sheet, confirm the formulation, concentration, pH, specific gravity, approved operating pressure range and boiler water control limits.
Alkalinity control makes sludge in soft form, which can be easily blown down from bottom side of BOILER.
Other valuable Boiler Water Treatment Chemical product :
| RXSOL-50-5020-025 | Boiler Water Treatment Auto |
| RXSOL-40-4091-025 | Scale and Corrosion Inhibitor for Cooling Water |
| RXSOL-40-4009-025 | MICRO BIOCIDE Cooling Water |
| RXSOL-50-5002-025 | Alkalinity Control |
| RXSOL-40-2000-025 | RXSOL 2000 corrosion inhibitor |
| RXSOL-40-4009-025 | MICRO BIOCIDE Cooling Water |
| RXSOL-50-5021-025 | Hardness Control Liquid |
Alkalinity Builder to maintain pH of Boiler WATER.
Alkalinity Control : Alkalinity Control is a concentrated liquid alkaline product for corrosion and scale control in boilers.
Boiler Water Treatment Chemicals Full range ::: https://rxchemicals.com/Boiler-treatment-chemicals-INDIA-One-Stop-Boiler-Maintenance-Solutions
Marine Chemicals Full Range Link ::: https://marinechemical.in/marine-chemicals-full-range
PRODUCT BULLETIN
RXSOL ALCA SOLUTION
Product Category: Marine Boiler Water Treatment Chemicals Product Type: Alkalinity Control / Boiler Water pH Adjustment Brand: RXSOL
1. Product Description
RXSOL ALCA SOLUTION is a liquid alkaline treatment chemical designed to maintain the required alkalinity and pH in marine and industrial boiler water systems.
Proper boiler water alkalinity is essential for minimizing acidic corrosion, supporting effective phosphate treatment and maintaining suitable operating conditions within the boiler.
RXSOL ALCA SOLUTION is intended to correct low boiler water pH and maintain the alkaline conditions required for reliable boiler operation.
The product can be incorporated into a coordinated boiler water treatment programme alongside oxygen scavengers, hardness control chemicals and condensate treatment products.
2. Key Features & Benefits
-
Raises and controls boiler water pH.
-
Helps maintain the required boiler water alkalinity.
-
Reduces the risk of acidic corrosion.
-
Supports effective boiler water treatment programmes.
-
Suitable for controlled dosing into compatible boiler systems.
-
Liquid formulation facilitates chemical dosing.
-
Helps maintain suitable conditions for phosphate-based boiler treatment.
-
Supports efficient boiler maintenance and operation.
-
Suitable for marine auxiliary boilers and selected industrial steam boilers.
3. Major Applications
Marine Auxiliary Boilers: Alkalinity adjustment in suitable shipboard boiler water systems.
Industrial Steam Boilers: Maintenance of boiler water pH and alkalinity within the required operating range.
Boiler Water Treatment Programmes: Used alongside compatible oxygen scavengers and hardness control treatments.
Steam Generation Systems: Supports water chemistry control in appropriate boiler applications.
4. Typical Product Properties
|
Property |
Description |
|---|---|
|
Product Name |
ALCA SOLUTION |
|
Brand |
RXSOL |
|
Appearance |
Liquid |
|
Chemical Nature |
Alkaline treatment solution |
|
Primary Function |
Boiler water alkalinity and pH control |
|
Solubility |
Water-soluble formulation |
|
pH |
Alkaline; exact value to be confirmed |
|
Specific Gravity |
To be confirmed |
|
Application |
Boiler water treatment |
|
Dosing Method |
Controlled chemical injection |
|
Packing |
Subject to confirmation |
The exact chemical composition, concentration, density and pH of RXSOL ALCA SOLUTION have not been provided. These specifications require confirmation from the approved formulation.
5. Working Principle
RXSOL ALCA SOLUTION increases the alkalinity of boiler water and helps maintain the required pH.
Proper alkalinity control helps minimize corrosion caused by acidic conditions and supports the performance of other boiler water treatment chemicals.
However, excessive alkalinity may contribute to foaming, carryover, caustic concentration and other operational problems.
The treatment must therefore be controlled through regular boiler water analysis.
6. Directions for Use
-
Test boiler water pH and alkalinity.
-
Compare the results with the boiler manufacturer's recommended operating limits.
-
Calculate the required chemical dosage based on the boiler water volume and product concentration.
-
Introduce the chemical through an approved dosing system.
-
Allow adequate circulation and mixing.
-
Retest the boiler water and adjust dosing as required.
-
Maintain appropriate blowdown and routine water testing.
Important: Do not dose concentrated alkaline chemical directly into an unsuitable or isolated section of the system. Follow the equipment manufacturer's chemical injection requirements.
7. Boiler Water Parameters to Monitor
|
Parameter |
Purpose |
|---|---|
|
pH |
Control of boiler water acidity/alkalinity |
|
P-Alkalinity |
Monitoring boiler alkalinity |
|
M-Alkalinity |
Assessment of total alkalinity |
|
Phosphate |
Hardness control where phosphate treatment is used |
|
Chloride |
Monitoring dissolved salt concentration |
|
Conductivity |
Control of dissolved solids |
|
Dissolved Oxygen |
Corrosion control |
|
Sulphite Residual |
Oxygen scavenger monitoring where applicable |
8. Safety & Handling
-
Read the latest Safety Data Sheet before use.
-
Wear chemical-resistant gloves and eye/face protection.
-
Avoid contact with skin and eyes.
-
Do not mix concentrated product with acids.
-
Use suitable chemical-resistant dosing equipment.
-
Store in tightly closed, compatible containers.
-
Prevent uncontrolled discharge into the environment.
Warning: Concentrated alkaline formulations may be corrosive. Hazard classification must be based on the actual chemical composition.
9. Storage
Store in a cool, dry, well-ventilated area away from incompatible chemicals.
Keep containers tightly closed and properly labelled.
Protect from contamination and extreme temperatures.
RXSOL ALCA SOLUTION – Marine Chemical Supplier
RXSOL CHEMO PHARMA INTERNATIONAL
Product: ALCA SOLUTION Category: Marine Boiler Water Treatment / Alkalinity Control
India: www.rxmarine.com UAE: www.dubichem.com Oman: www.omanchem.com
Technical note: This bulletin assumes ALCA SOLUTION is an alkaline boiler water treatment product. If your product is instead an alkaline tank cleaner or a different formulation, its description and applications will need to be revised accordingly.
How RXSOL Alkalinity Control Works
1. Increases Boiler Water Alkalinity
The alkaline components increase hydroxide ion concentration, raising boiler water pH and alkalinity.
2. Supports Corrosion Control
Maintaining suitable alkalinity helps reduce acidic corrosion and supports the stability of protective oxide films on compatible boiler metals.
3. Supports Phosphate Treatment
Phosphate-based hardness treatment requires controlled boiler water chemistry. Proper alkalinity helps maintain suitable conditions for phosphate treatment and sludge management.
4. Maintains Boiler Water Chemistry
Controlled chemical addition helps compensate for alkalinity losses caused by makeup water, blowdown and changing operating conditions.
The presence of alkalinity in a water sample may be due to many different substances. However, for the sake of simplicity, the presence of bicarbonate, carbonate, and hydroxide ions is commonly considered as alkalinity. The points of change in colour of phenolphthalein and methyl orange indicators, which occur at pH 8.3 and pH 4.3 provide standard reference points which are almost universally used to express alkalinity.
Very high alkalinity values can be undesirable in an industrial water supply. For example, the presence of a high methyl orange alkalinity should be avoided in boiler feed water because of the resultant carbon dioxide content of the steam. Carbon dioxide usually is responsible for the corrosion of steam and return lines. High boiler water alkalinities are also undesirable because the presence of high hydroxide ion concentration is the primary cause of caustic metal embrittlement. A very high boiler alkalinity can also lead to an undesirable carryover condition. On the other hand, the alkalinity of boiler water must be sufficiently high to protect the boiler metal against acidic corrosion and to ensure precipitation of scale-forming salts. Usual treatment approaches include setting both a minimum alkalinity level and an operating range.
Hydroxide alkalinity may be determined by adding barium chloride prior to titration to precipitate the carbonate ion from solution, allowing direct titration of the hydroxide alkalinity. Measurement of hydroxide alkalinity is also used to control lime soda softeners.
In cooling water systems, alkalinity is of major importance since the total alkalinity of a water is one factor that must be considered when predicting the tendency for the water to precipitate calcium carbonate scale. Depending on the choice of chemical treatments to protect against corrosion and scale formation, the operating alkalinity and pH ranges are chosen to balance these two features.
Alkalinity Titrimetric Method (0-200 ppm)
Principle Theory
This test is based on the determination of alkalinity by titration with standard acid to the phenolphthalein color change (or to a pH of 8.3) and to the methyl orange color change (or a pH of 4.3). For determination of hydroxide alkalinity only, barium chloride is added prior to titration to precipitate the carbonate ions. Titration is then taken only to the phenolphthalein end point. A pH meter may be used instead of the indicators to determine the end points of the titration.
Key Features and Benefits
-
Boiler Water pH Control: Helps maintain the required alkaline operating conditions.
-
Corrosion Prevention: Reduces the risk of acidic corrosion associated with insufficient alkalinity.
-
Alkalinity Adjustment: Supports control of boiler water hydroxide alkalinity.
-
Phosphate Treatment Support: Helps maintain conditions necessary for effective phosphate-based hardness control.
-
Concentrated Formulation: Allows controlled chemical dosing.
-
Marine Boiler Applications: Suitable for treatment programs used in marine auxiliary boiler systems.
-
Industrial Boiler Protection: Supports routine boiler water conditioning in industrial steam systems.
-
Improved Operational Reliability: Helps reduce problems associated with improper boiler water chemistry.
It can also be used as a neutralizing agent following acid cleaning with descaling materials ( RXSOL-11-1008--DC descaling Liq / RXSOL-54-1008-SA Safe Acid PWD )
CHARACTERISTICS
- Alkalinity Balace mechnism to control corrosion.
- It converts calcium hardness into soft, non-adherent sludge that is easily removed by blowdown. Treated as good salt-scale controler product.
- Compatible with other BOILER chemicals
- Tested with long and continious running plant for more then 20 Years and easy to apply and use.
- Avoid contact with any acidic / oily - FAT materials.
Safety Data (MSDS)

| Product Name | : | RXSOL-50-5002-025 |
| Product Type | : | ALKALINITY CONTROL 25 Ltr |
Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
Stock Point : Mumbai, Kandla, Surat, Kolkata, Chennai, Visakhapatnam, Fujairah, Muscat
| Phone | : | +91 22 27815541 / 42 |
| Fax | : | +91 22 2781 1318 :::AOH :0091 9821214367 |
| : | mail@rxmarine.com |

|
Chemical Name |
Concentration |
CAS Number |
EC Number |
R Phrases* |
Symbols |
|
Metalic hydroxide which includes Sodium Hydroxide |
27 - 36 |
1310-73-2 |
215-185-5 |
35 |
C |
|
Non classified ingredients |
64-73 |
These products are not classified as hazardous and lower then hazard limits |
NA |
NA |
NA |
*See Section 16

![]()
Corrosive
|
Odour |
Odourless. |
|
Appearance |
Liquid, colourless to yellow, soluble in water. |
|
Contact with eyes |
Corrosive to eyes Can cause damage to the eyes. |
|
Contact with skin |
Causes severe burns (R35). |
|
Inhalation |
No information available but must be considered harmful. |
|
Ingestion |
Harmful if swallowed (R22). |

|
Contact with skin |
Remove contaminated clothing immediately and drench affected skin with plenty of water Then wash with soap and water.Seek medical advice if necessary |
|
Contact with eyes |
If the substance has got into eyes, immediately wash out with plenty of water for at least 15 minutes. Irrigate eyes thoroughly whilst lifting eyelids.Obtain immediate medical attention. Continue flushing with water until medical help arrives |
|
Ingestion |
Do not induce vomiting.Never give anything by mouth to an unconscious person.Give water or milk to drink.Obtain immediate medical attention. |
|
General |
In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible) (S45) -When in doubt or symptoms persist, seek medical attention |

- Non-combustible
- Smoke from fires is corrosive
- Not flammable. In case of fire use extinguishing media appropriate to surrounding conditions
- Vapour density - not applicable

|
Personal Precautions |
Wear protective clothing as per section 8. |
|
Environmental Precautions |
Do not flush spilt material into any public water system. |
|
Clean Up Actions |
Absorb spillage in inert material and shovel up.Ventilate the area and wash spill site after material pickup is complete.Neutralise with Acid. |
|
Special Precautions |
Wear protective clothing as per section 8. |

|
Handling |
Eyewash bottles should be available.See Section 8 |
|
Storage |
Keep only in the original container in a cool, well-ventilated place (S3/9/49).Protect from frost. |

|
Exposure Limits |
OES / LTEL # ppm 2 mg/m3.(Sodium hydroxide) |
|
Exposure controls |
No special ventilation is required unless the product is used in a spray form |
|
Occupational exposure controls |
Wear suitable protective clothing, including eye/face protection and gloves (plastic or rubber are recommended).During fumigation/spraying wear suitable respiratory equipment (S42) |
![]()
Gloves Suit Goggles No_Smoking

|
Odour |
Odourless |
|
Appearance |
Liquid, colourless to yellow, soluble in water |
|
PH |
11.5 - 12.5 at 0.1 % concentration , Neat : 14.0 |
|
Boiling point |
100 °C at 760 mm /Hg |
|
Vapour pressure |
Not known |
|
Vapour density |
Not applicable |
|
Freezing point |
0 °C at 760 mm/Hg |
|
Completely soluble in water |
|
|
Specific gravity |
(water=1) 1.50 |
|
Non-combustible |
|

- This article is considered stable under normal conditions
- Avoid overheating, Keep away from frost
- Incompatible with acid
- See Section 5

|
Toxicological information |
The ingestion of significant quantities may cause burning sensation.Can cause damage to the digestive system. |
|
Inhalation |
Not regarded as a potential route of exposure. Can cause damage to the respiratory system. |
|
Contact with skin |
Causes severe burns (R35) |
|
Contact with eyes |
Causes severe burns (R35) |
|
Ingestion |
The ingestion of significant quantities may cause damage to the digestive system. |
|
Carcinogenicity |
No evidence of carcinogenic effects. |

|
Ecotoxicity |
May cause acute effects in the aquatic environment. |
|
Mobility |
Completely soluble in water. |
|
Persistence and Biodegradability |
Degrades by hydrolysis |
|
Bioaccumulation Potential |
Bioaccumulation is insignificant |
|
Other Adverse Effects |
No environmental problems are expected when the product is used/handled correctly. In its intended use, the product will not be released into the environment. |

|
Classification |
This material and/or its container must be disposed of as hazardous waste.EU Waste class: 06 02 02 |
|
Disposal considerations |
Do not discharge into drains or the environment, dispose to an authorised waste collection point.Disposal should be in accordance with local, state or national legislation |

| Proper Shipping Name: | ||||
| UN | ||||
| Proper Shipping Name | Sodium hydroxide. solution | |||
| UN NO. | 1824 | |||
| Hazard Class | 8 | Packing Group | II | |
| Road/Rail (ADR/RID) | ||||
| Proper Shipping Name | Sodium hydroxide. solution | |||
| ADR UN No. | 1824 | |||
| ADR Hazard Class | 8 | Termcard | 80S1824 | |
| Sear (IMDG) | ||||
| Proper Shipping Name | Sodium hydroxide. solution | |||
| IMDG UN No. | 1824 | |||
| IMDG Hazard Class | 8 | IMDG Pack Group | II | |
| IMDG EmS | F-A, S-B | IMDG subrisk | NA | |
|
Air(ICAO/IATA) |
||||
| ProperShippingName: |
Sodiumhydroxide, solution |
|||
| ICAO UnNo.: | 1824 | |||
| ICAO HazardClass.: | 8 | ICAO PackingGroup.: | II | |
| ICAO subrisk: |
N/A |
ICAO Labels | 8, CAO | |
| ICAO Flashpoint: |
N/A |
|||
| DOT/CFR(USDepartment ofTransportation | ||||
| DOTProperShippingName: | Sodium hydroxide, solution | |||
| hazardous material | Sodium hydroxide | |||
| Hazard Class: | 8 | IdentificationNumber: | UN1824 | |
| Product RQ (lbs): | 3640 | DOTsubrisk: |
N/A |
|
| DOTLabels: | 8 | DOTFlashpoint: | N/A | |

|
Risk Phrases |
Causes severe burns (R35) |
|
Safety Phrases |
In case of contact with eyes, rinse immediately with plenty of water and seek medical advice (S26).Wear suitable protective clothing, eye/face protection (S36/39).In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible) (S45) |

The text of R and S phrase codes used in this safety data sheet:- R35: Causes severe burns.The information provided about the product on this Safety Data Sheet has been compiled from knowledge of the individual constituents The data given here is based on current knowledge and experience. This Safety Data Sheet describes the product in terms of safety requirements and does not signify any warranty with regard to the product's properties.The data given here only applies when product used for proper application(s). The product is not sold as suitable for other applications - usage in such may cause risks not mentioned in this sheet. Do not use for other application(s) without seeking advice from manufacture This Safety Data Sheet is provided in compliance with The Dangerous Substances Directive (67/548/EEC) This Safety Data Sheet is provided in compliance with The Dangerous Preparations Directive (88/379/EEC) This Safety Data Sheet is provided in compliance with The Safety Data Sheets Directive (2001/58EC)
DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.